为什么在进行带缓冲区的计数器操作时出现错误 -10920? 我在一台奔腾III的计算机上做带缓冲区的周期测量,但是我总是碰到错误 -10920, 提示信息是有些采样点因为我的电脑的速度限制未能读取。为什么即使在测一个低频信号的时候,我仍然会碰到这个错误?我该如何避免这个错误? URL: http://digital.ni.com/public.nsf/allkb/820549D0D2C4F931482573930024AE5F
62xx 보드에서 카운터 입력을 사용할때 발생하는‘Error -200452 occurred at Property Node DAQmx Channel’ 여러개의 카운터 펄스 태스크를 사용하는 어플리케이션을 실행하면 충돌이 나고 -200452 에러가 발생합니다. DAQmx 카운터 태스트는 ■> URL: http://digital.ni.com/public.nsf/allkb/7519675DD826969886257235000AA4CC
‘Error -200452 occurred at Property Node DAQmx Channel’ When Using Counter Inputs On a 62xx Card An application using multiple counter pulse tasks crashes when run and generates error -200452. DAQmx counter tasks use Direct URL: http://digital.ni.com/public.nsf/allkb/2B9E611D611EFC0D8625722D00645A18
Error -200251: 'No DMA Channels Available' Cuando Utilizo Multiples Contadores Estoy realizando más de tres tareas de entrada de contadores de forma simultanea en una NI 6602 o NI 6608, o estoy realizando más de una tarea de entrada de contador en una PCI-6601. Después de agregar una tarea adicional y ejecutar, el siguiente error ocurre en DAQmx Start URL: http://digital.ni.com/public.nsf/allkb/E53FA6E6A18A12808625745A006F8F50
Error -200251: 'No DMA Channels Available' When Using Multiple Counters I am doing more than three simultaneous counter input tasks on a NI 6602 or NI 6608, or I am doing more than one simultaneous counter input task on a PCI-6601. After adding an additional task and running, the following error occurs at DAQmx Start URL: http://digital.ni.com/public.nsf/allkb/6503B2EFA2CB867186257219007DB643
当使用多个计数器的时候发现错误-200251:“没有多余的DMA通道(No DMA Channels Available)” 我再NI 6602或者NI 6608上采用多于三个计数器同时进行计数器输入的任务。或者在PCI-6601上采用超过一个计数器进行计数器输入的任务。 当我再添加一个任务并开始运行的时候,在DAQmx Start Task中出现了以下错误: URL: http://digital.ni.com/public.nsf/allkb/E885F195EE56A42B862573CA00439E9D
複数カウンタを使用する際、エラーー200251が出ますがなぜでしょうか。 PCI-6601及びPCI-6602またPCI-6608を使用して、それぞれ2つ及び4つ以上の同時カウンタ入力タスクを作成しています。このVIを実行しますと、DAQmx Start Task VIからー200251のエラーが出ます。エラーの内容としては、DMAチャネルまたはUSBバルク終了点が無効■> URL: http://digital.ni.com/public.nsf/allkb/7AC693B7676D4F4086257385003F0FFB
'Not Responding to the Selected Base Address'错误 在安装/使用我的数据采集板卡的时候,我收到了"Not Responding to the Selected Base Address"错误 URL: http://digital.ni.com/public.nsf/allkb/6A3F8E225FAB4797482571F80028B290
Error at Line Set Attribute for TIO Application I have a Traditional DAQ Counter/Timer VI that worked in LabVIEW 6.1 but errors at Line Set Attribute in LabVIEW 8 URL: http://digital.ni.com/public.nsf/allkb/47A14AF259407A3A8625712700027582
TIO 어플리케이션의 Line Set Attribute 에서의 에러. LabVIEW 6.1 에서 사용하던 Traditional DAQ 카운터/타이머 VI 를 가지고 있는데 LabVIEW 8 에서는 Line Set Attribute 에서 에러가 발생합니다. URL: http://digital.ni.com/public.nsf/allkb/B84876747FDF3E41862571310001A63C