Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Bug Fix/ Error Message/ Error Code [remove] ,
Hardware
: Modular Instruments [remove] ,
1-10 of 81
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Calibration Executive (3)
Driver Software (21)
LabVIEW Development Systems (5)
LabVIEW Toolkits (2)
LabWindows/CVI Development Systems (1)
Measurement Studio (1)
Other NI Software (1)
Hardware
Digital Multimeters (DMM) (12)
Dynamic Signal Acquisition and Analysis (DSA) (23)
High-Speed Digitizers (Scopes) (29)
High-Precision DAQ (Dataloggers) (4)
RF Measurement Devices (10)
Document Languages
English (46)
Spanish (1)
Japanese (4)
Chinese (Simplified) (15)
Chinese (Traditional) (7)
Korean (8)

Sort by:
1-10 of 81
Sample Rate Error -1074135016 or -1074118530 when Using the NI-SCOPE Property Node Why do I get errors -1074135016 or -1074118530 when using the NI-SCOPE property node to configure horizontal properties? The error message tells me that I have set my sampling rate too high, but I know I have set it below the maximum rate of my scope. URL: http://digital.ni.com/public.nsf/allkb/74C7109C66B5D304862573BE005726D8
Lazo de Seguimiento de Fase (PLL) a un Reloj de Referencia Externa en NI-SCOPE Estoy tratando de realizar un seguimiento de fase en lazo (PLL) con un reloj externo en mi tarjeta digitalizadora. Ya he configurado mi reloj de referencia (reference clock) para recibir una entrada externa usando la función: “NI Scope Configure Clock.vi” en LabVIEW, pero URL: http://digital.ni.com/public.nsf/allkb/0E382A367F97B090862573AE006FB067
NI-DAQmx Error -50103 When Performing AI and AO on an NI 4461 When I use the Multi-Device Sync-AI and AO-Shared Timebase & Trig-DSA shipping example or when I try to synchronize Analog Output (AO) and Analog Input (AI) on my NI 4461 DSA card I URL: http://digital.ni.com/public.nsf/allkb/8C7A7AF1A6DDD00086257399005B8513
Error-50251 When Performing Self-Calibration on My NI-5922 After Upgrading from NI-SCOPE 3.3.2 to NI-SCOPE 3.4 Previously I had NI-SCOPE 3.3.2, which I had installed from the August 2007 device driver CDs. I recently upgraded my NI-SCOPE driver to version 3.4 and now I cannot self-calibrate my NI-5922. In Measurement and Automation Explorer the self-calibrate option is disabled and I do not see any URL: http://digital.ni.com/public.nsf/allkb/B84AE4281BA524508625737C005375AF
Using NI-Scope With Traditional NI-DAQ Devices on Vista Causes System Crash on Hibernation The kernel crashes when coming out of hibernation if I am acquiring data on a PXI-5112 or PXI-5102 running when Windows Vista™ was placed into hibernation. URL: http://digital.ni.com/public.nsf/allkb/F9D9DC2335634C79862572F0005BA040
NI PXI-5600/5661 Self Test Failure After Previous Use as NI PXI-5600/5660 I am using an NI PXI-5600 as the downconverter for an NI PXI-5661 vector signal analyzer that was previously used as the downconverter for an NI PXI-5660 vector signal analyzer, but a self-test in MAX displays a failure error code -200324 as shown in the following image: URL: http://digital.ni.com/public.nsf/allkb/854B88A025BDB5FE862572A0004D3928
NI DMM Error -1074118625: Volt-Hz Common Mode Limit I am using an NI DMM, and occassionally run into the following error: "Error -1074118625: niDMM Read Waveform (waveform data).vi. The Volt-Hz common mode limit has been exceeded." What does this error mean, and what can I do to remedy it? URL: http://digital.ni.com/public.nsf/allkb/A593DEBFD86A69C68625727900748EEC
如何配置NI-5152的实时采样率在1GSa/s和2GSa/s之间 使用NI-5152,当我设置采样率大于1GSa/s时,会报如下图所示的错误。我如果想让NI-5152工作在2GSa/s,该如何配置? URL: http://digital.ni.com/public.nsf/allkb/0DD0BA9D712666628625735B000DB934
NI Scope 與外部參考時脈(External Reference Clock)作鎖相迴路(PLL) 我試著讓我的 NI-Scope 卡片與外加的參考時脈作鎖相同步(PLL)。我已經在 LabVIEW 中用 NI Scope Configure Clock VI 設定了外加的參考時脈,但是當我執行程式時,發生了 "Error -1074115830 occurred at niScope Initiate Acquisition.vi" URL: http://digital.ni.com/public.nsf/allkb/197AEDC0AB13573E862572DE0046762E
NI Scopes에서 외부참조클럭을 이용한 PLL National Instruments Scopes에서 외부참조클럭을 이용한 PLL 을 하려고 합니다. LabVIEW에서 NI Scope Configure Clock VI 함수를 사용하여 참조클럭을 외부 입력으로 설정하였습니다. 그러나 프로그램을 실행하면 다음과 같은 에러가 발생합니다.'Error -1074115830 occurred at niSco URL: http://digital.ni.com/public.nsf/allkb/557C511EDD3C6915862572120026B2C2
Sort by:
1-10 of 81