USB 232/4 Device Shuts Down
My USB 232/4 device works for a while and suddenly turns off and then back on after a couple of minutes. I have already checked the USB power settings in Device Manager to disable allowing to turn off device for power savings. I also verified that only one device is connected to one USB root
URL: http://digital.ni.com/public.nsf/allkb/9D3890BE49FF5D43862573A7006E5612
|
Why Does My GPIB-USB-HS Device Prompt the Add Hardware Wizard Each Time I Plug it in?
Every time I unplug my GPIB-USB-HS device and plug it back in, the Add Hardware Wizard pops up and re-installs the drivers. Each time this happens I lose all of the device configuration settings. How can I avoid this?
URL: http://digital.ni.com/public.nsf/allkb/13B27DA885E3F3D2862572CA0065FF70
|
Using NI-845x i2c and SPI Refnums with TestStand
I am trying to store references from the NI-845x driver VIs to a TestStand global variable, but when I run my sequence I receive the error '-17313; Could not accept the parameter passed in.' How can I pass NI-845x refnums into TestStand?
URL: http://digital.ni.com/public.nsf/allkb/F17822F5C2B5E8FE862571410080FAA0
|
Sony製のIEEE1394カメラDFW-SX900で画像が集録できない時の対応方法
NI-IMAQ for 1394 Ver2.0.2とSony製のIEEE1394カメラ DFW-SX900を使っています。デバイスマネージャーでの認識もMAXでの認識も問題ないのですが、画像の集録ができません。どうしたら画像が集録できるようになりますか?
URL: http://digital.ni.com/public.nsf/allkb/42A192CA7A2E0ACE862571240017A5E2
|
I Can't Run the NI 488.2 Troubleshooting Wizard Without Failure Unless I am an Administrator
I do not have administrator access on my computer. When I try to run the NI 488.2 Troubleshooting Wizard, it fails on the last step. What is wrong?
URL: http://digital.ni.com/public.nsf/allkb/265E740C9541FF6986256D890080446F
|
GPIB-ENET/100 Fails 'ibtsta' on Solaris 8
My GPIB ENET-100 fails the ibtsta verification test with an error of ENEB. I can see my ENET/100 in the Ethernet Configuration Utility and I can 'ping' it successfully. Why does the 'ibtsta' test fail?
URL: http://digital.ni.com/public.nsf/allkb/C1221E8E3B12204B86256CC700713F70
|
'Access Denied' Message During GPIB-USB Device Installation
I am trying to install my GPIB-USB controller on my Windows 2000/XP machine. After I install the driver, NI-488.2, I reboot the PC, and after it powers up, I plug in my GPIB-USB device in the USB port. The Found New Hardware messages pops up, and after the initialization message, I get an
URL: http://digital.ni.com/public.nsf/allkb/1D52B53149DD637686256CAA00565E47
|
Run-Time Error 48 When Calling a GPIB Function in Visual Basic
I installed the GPIB-USB-A on my Windows 2000 PC. It installs, tests, and locates an instrument correctly. When I run a sample Visual Basic application, I get the following error message: Run time error '48': File not found Gpib-32.dll.
URL: http://digital.ni.com/public.nsf/allkb/247B1FAB9C23DA4686256B95006C99FC
|
當在Visual Basic下使用GPIB函式時出現錯誤 Run-Time Error 48
我在灌Windows 2000的電腦下安裝GPIB-USB-A。GPIB-USB-A用來安裝、測試、尋找儀器都很正常。可是當我執行一個簡單的Visual Basic應用程式時,我得到以下的錯誤訊息: Run time error '48': File not found Gpib-32.dll.
URL: http://digital.ni.com/public.nsf/allkb/B5650AC47D82411C8625733A004B88DA
|
PROSet EEPROM Test May Fail with the PCI-8212, PXI-8211, or PXI-8212
When running the Intel PROSet diagnostics on one of these boards, the EEPROM test may fail. Is my EEPROM bad?
URL: http://digital.ni.com/public.nsf/allkb/862567530005F09F862569EC004773D2
|