Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Question Type
: Bug Fix/ Error Message/ Error Code [
remove
] ,
Hardware
: Compact FieldPoint [
remove
] ,
11-20 of
35
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
LabVIEW Development Systems
(2)
LabVIEW Modules
(6)
Calibration Executive
(1)
Driver Software
(2)
LabVIEW Run-Time Engine
(1)
Hardware
Controllers
(16)
Analog I/O Modules
(4)
Discrete I/O Modules
(8)
Connector Blocks
(1)
Document Languages
English
(29)
Spanish
(2)
Chinese (Simplified)
(1)
Korean
(3)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
35
Previous
|
Next
Why Can't I See Some Of My cFP Modules on my cFP-180x in MAX?
I have a cFP module plugged into my cFP-180x but I can't see it in MAX. I have another of the exact same type of module and it shows up correctly. Is my hardware broken?
URL:
http://digital.ni.com/public.nsf/allkb/15B2E18BAE8E43C08625731C0070FB4B
为什么我在MAX中无法看到我的cFP-180x上的一些cFP模块?
我的cFP-180x上插入了一个cFP模块,但是我无法在MAX中看到。我有另外一个相同类型的模块,正确的显示在MAX中,是不是该模块坏了?
URL:
http://digital.ni.com/public.nsf/allkb/4228B9893AF82011862573D70041EFF9
Why Do I Get Error 63 When Updating the Software on my FieldPoint?
I am using the following software: LabVIEW Real-Time 6.X FieldPoint OS 9.X Why do I get error 63 when I attempt to update the OS or installed software?
URL:
http://digital.ni.com/public.nsf/allkb/80C1B751253C8F40862572CF000D36BE
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration?
I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but
URL:
http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
'Unable to connect to the data item on the module' Error When Attempting to Find Devices with FieldPoint
My FieldPoint shows up in Measurement & Automation Explorer (MAX), I have assigned it an IP address, and I've installed LabVIEW RT. However, I cannot successfully Find Devices. What do I need to do in order to find devices on my FieldPoint?
URL:
http://digital.ni.com/public.nsf/allkb/7BE0E528D913BCC3862573EC005D031D
cFP-DI-304 Update Utility
Why does my cFP-DI-304 return incorrect data when performing a single FieldPoint Read?
URL:
http://digital.ni.com/public.nsf/allkb/C63537BEF87A62A58625728F00727FB2
Unresolved Dependencies Error when Installing Software to cFP, cRIO, or PXI Targets
I am trying to install LabVIEW Real-Time software on my target cRIO, cFP, or PXI Real-Time device. When I right click and click Add/Remove Software on my remote system and select LabVIEW Real-Time or other software, it gives me an error, “Cannot continue because of the
URL:
http://digital.ni.com/public.nsf/allkb/961D2DC5BB2991F88625727A00736A7F
Error -1950678986 Using Shared Variables Bound to Fieldpoint I/O Items
I have a shared variable bound to a channel on my FieldPoint and whenever this channel goes Out of Range my shared variable reads are returning an error -1950678986 Unspecified shared variable error. Is this expected behavior when my FieldPoint
URL:
http://digital.ni.com/public.nsf/allkb/74C5B198E4FE19AD86257214007F064A
Fieldpoint I/O 아이템에 묶여있는 공유변수를 사용할때 발생하는 -1950678986 에러
FieldPoint의 채널에 묶인 공유변수를 사용하고 있습니다. 그런데 이 채널들이 Out of Range가 되면, 읽기 공유변수들은 에러-1950678986 Unspecified shared variable error를 발생시킵니다. 이 에러는 FieldPoint 채널의 값이 영역 밖으로 나가게 되면
URL:
http://digital.ni.com/public.nsf/allkb/56E930226BE67ACE8625721F001D752B
Detecting Modules on the cFP-2010 with Real-Time 6.1.3
I have a cFP-2010 and when I try to have MAX recognize my modules by clicking Find Devices it doesn't find anything. I am running LabVIEW Real-Time 6.1.3. How can I get my modules to appear?
URL:
http://digital.ni.com/public.nsf/allkb/3DE0FEF54002944C8625721000809581
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
35
Previous
|
Next
Search KnowledgeBase Documents: