Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Bug Fix/ Error Message/ Error Code [remove] ,
Software
: Calibration Executive [remove] ,
1-10 of 32
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Compact FieldPoint (1)
CompactDAQ (1)
CompactRIO (1)
FieldPoint (1)
Modular Instruments (3)
SCXI (2)
Document Languages
English (30)
Chinese (Simplified) (1)
Korean (1)

Sort by:
1-10 of 32
Calibration Executive is giving Error -1074001424 When Calibrating a PCMCIA-4050 Why am I receiving error -1074001424 trying to calibrate my PCMCIA-4050 with Calibration Executive? URL: http://digital.ni.com/public.nsf/allkb/4D4E9D5DE63C562D862573BE005D98CC
Error 1074118637 in Calibration Executive when Calibrating a DMM The error below is occuring in Calibration Executive when trying to calibrate a DMM from National Instruments: Error -1074118637 occurred at niDMM Read.vi at step Re-verify ACVoltage Possible reason(s): There is an error in the URL: http://digital.ni.com/public.nsf/allkb/46F62B301745498C8625730200754A14
PXI-4072 Failing Calibration in Calibration Executive 3.2.1 When performing a calibration of a PXI-4072 in Calibration Executive 3.2.1 my calibration always fails. Why does the failure always occur during the Capacitance Verification step? URL: http://digital.ni.com/public.nsf/allkb/5C047112BCD6B10E862572D000441A1F
Error -200152 after running my PXI-4472 through Calibration Executive After performing a calibration through Calibration Executive 3.1.2, my PXI-4472 always returns Error -200152: Data read from the EEPROM on the device is invalid. whenever I try to use the device. This occurs in my application and in MAX through Test Panels. Why URL: http://digital.ni.com/public.nsf/allkb/CD5822581645D90C862572BC005EA7B2
Error -17208 When Using SCXI-1104 with Calibration Executive 3.2 Error -17208 is returned when calibrating an SCXI-1104 with Calibration Executive 3.2. URL: http://digital.ni.com/public.nsf/allkb/2FC4059D33FEF318862572BB0043704C
Error -200077 When Using an NI 9263 with Calibration Executive 3.2 When I attempt to calibrate an NI 9263 (cRIO/cDAQ module) with Calibration Executive 3.2, I'm presented with error -200077. URL: http://digital.ni.com/public.nsf/allkb/F979EC662795C43C862572B80081D469
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration? I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but URL: http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
Error -17208 when Calibrating an SCXI-1104 with Calibration Executive 3.2 Why do I receive error '-17208, File or directory not found' when I try to calibrate my SCXI-1104 with Calibration Executive 3.2? URL: http://digital.ni.com/public.nsf/allkb/D550648B1D6C563886257288005490AF

Calibration Executive Error -17313
I just installed Calibration Executive 3.1; why do I get error -17313 whenever I try to run a calibration procedure? URL: http://digital.ni.com/public.nsf/allkb/9FA8469DB891721B8625724000823F77
Error 1074135039 With Calibration Executive and PXI-4060 I am using Calibration Executive 3.1 to calibrate my PXI-4060. My calibrator is the Fluke 5700A. When the procedure reaches the 'AC Volts Verification' step, it gives error 1074135039. At this time, the 5700A displays a value of 237.5 V DC on its screen. What is the problem? URL: http://digital.ni.com/public.nsf/allkb/CD73E8828F726C788625720B0050964D
Sort by:
1-10 of 32