Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Question Type
: Bug Fix/ Error Message/ Error Code [remove] ,
Software
: LabWindows/CVI Development Systems [remove] ,
1-10 of 161
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Base Package (32)
Full Development System (134)
Hardware
Digital I/O (DIO) (2)
GPIB (1)
Instrument Connectivity Other (1)
Modular Instruments (1)
Multifunction DAQ (MIO) (1)
Document Languages
English (139)
Spanish (4)
Japanese (3)
Chinese (Simplified) (5)
Chinese (Traditional) (6)
Korean (4)

Sort by:
1-10 of 161
CVI Crashes Because Installation is Missing visainfo.ini When I attempt to launch the LabWindows/CVI environment after installation, I receive the following error message: Loading of VISA type and constant information from visainfo.ini failed. File not URL: http://digital.ni.com/public.nsf/allkb/CEFF428B8EECFEB48625746B006B7EEB
VLM Network Installer Causes Error -12 When Building Distribution in Application Builder I installed an Application Development Environment (ADE), such as LabVIEW, LabWindows\CVI, or TestStand, from a Volume License Manager (VLM) Network Installer. Now, I'm building a distribution of an application I wrote in this ADE, and I am including an Additional Installer of an NI component. URL: http://digital.ni.com/public.nsf/allkb/8325F41C38E16A1A862573ED000C9F6E
LabWindows/CVI Conversion Wizard in Visual Studio 6.0 Requires Absolute Paths for Function Panel Files When I use the LabWindows/CVI Project Conversion Wizard in Visual C++ 6.0, I receive errors saying that files are not found and that the project contains references to files that do not exist. The conversion wizard showed me a message that told me to open the project in CVI and update the URL: http://digital.ni.com/public.nsf/allkb/05284386D7761045862573DA0050A23E
TestStand cannot Load Object or Library files for CVI Adapter Using the CVI adapter in TestStand, I cannot load .obj or .lib files. I am using TestStand 4.0.1 or earlier and CVI 8.5 or later. URL: http://digital.ni.com/public.nsf/allkb/F071090755AB1EC9862573AD0062A04B
使用CVI Adapter時,TestStand無法載入Object或Library檔案 在TestStand中使用CVI adapter時,無法載入 .obj或 .lib檔案。我使用的版本為TestStand 4.0.1或先前的版本來搭配CVI 8.5或其後的版本。 URL: http://digital.ni.com/public.nsf/allkb/81CBD9A76B1CC8F686257447001A0E93
Distribution Not Found Error when Building Distribution in LabWindows/CVI When I try to build a distribution in LabWindows/CVI, I get the error "Distribution Not Found" and am unable to complete the distribution. Why do I get this error message? URL: http://digital.ni.com/public.nsf/allkb/E2D8B36AE74458C8862573A8005C4708
生成LabWindows/CVI安装包时报错Distribution Not Found 当我试图在LabWindows/CVI中生成安装包的时候,我获得 "Distribution Not Found" 的错误信息导致安装包不能创建完成。 为什么会出现这样的错误信息呢? URL: http://digital.ni.com/public.nsf/allkb/6AEFE379EC0C7F3386257425002E83AE
Why Do I Get 'Object Expected' Error When Opening Link in Function Panel Help? When I click on a link in a function panel help topic in LabWindows/CVI, I get the following URL: http://digital.ni.com/public.nsf/allkb/47839CF3A929B8CF862573450011F17C
Why Does My NI-Serial Troubleshooting Wizard Fail When Called From the System Exec Command? I am using the System Exec Command to call on the NI-Serial Troubleshooting Wizard (or possibly another application), and it fails the first test. If I run the Wizard any other way, it passes all tests. URL: http://digital.ni.com/public.nsf/allkb/02AC0D6B2602BD3D862572E9004DE990
Including NIDAQmx.h After nivxi.h Causes Redefinition Errors for the INT8 Datatype I have created a source file that simple includes the NIDAQmx.h and busacc.h header files. When I attempt to compile, the compiler complains that INT8 is attempting to be redefined twice. Also any other headers that rely on busacc.h or URL: http://digital.ni.com/public.nsf/allkb/DA8F8C42146D337B862572BC006F491D
Sort by:
1-10 of 161