Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Document Languages
: English [
remove
] ,
Hardware
: CompactDAQ [
remove
] ,
11-20 of
71
KnowledgeBase [
see results below
]. To refine your results, select another category.
Software
Calibration Executive
(1)
Driver Software
(8)
LabVIEW Modules
(3)
LabVIEW Signal Express
(3)
Utility Software
(1)
Hardware
Backplanes
(12)
Analog Input Modules
(36)
Analog Output Modules
(9)
Digital Input Modules
(6)
Digital Output Modules
(8)
Question Type
Bug Fix/ Error Message/ Error Code
(13)
FAQ
(18)
Install/Config
(9)
Programming
(8)
Specifications/ Documentation
(19)
Unexpected Behavior/ Bad Reading
(4)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
71
Previous
|
Next
Does the CompactRIO 9215 Module Have Anti-Alias Filters?
We recently purchased several cRIO NI 9215 modules together with a cRIO NI 9233 module. I was looking for information on the anti-alias filters and I found that the 9215 does not have anti-alias filter and the 9233 does. Why does the cRIO-9215 module not have anti-alias filters? Which
URL:
http://digital.ni.com/public.nsf/allkb/2C4C52B37819F838862573E20055F037
How do I configure the Input Range of the NI 9237?
The NI 9237 has an input range of 25 mV for every volt of excitation. Since this device can provide a maximum excitation voltage of 10 volts, I expect that a maximum input range of 250 mV. If I configure a task with an input range of more than 25 mV, I get error -200077: "Requested value is
URL:
http://digital.ni.com/public.nsf/allkb/8869E00B851A868E862573D80066A1FB
Different Types of Isolation: Channel-to-Channel, Bank (Channel-to-Bus), and Channel-to-Earth Ground Isolation
What are the differences between the types of electrical isolation NI offers on devices? I do not understand the differences between channel-to-channel, bank (channel-to-bus), and channel-to-earth ground isolation.
URL:
http://digital.ni.com/public.nsf/allkb/CF71091043A6193B862573D70077138B
How to Wire the Shield Pins of My 994x Terminal Blocks
I see the shield terminal on my 994x terminal block but I don’t know how to use it.
URL:
http://digital.ni.com/public.nsf/allkb/E14E3FC42DD02FFE862573D30005240E
What is the Maximum Number of Samples for Finite Analog Output on the USB-9263 ?
I would like to know the maximum sample count for finite analog output on the USB-9263.
URL:
http://digital.ni.com/public.nsf/allkb/3BC2397A164B8723862573B4007B572C
How do I force Windows to remove and redetect a USB device?
I have to disconnect and then reconnect my USB device for Windows before it will work. This often happens after losing power to the device but not to the computer. How can I do this manually, without having to physically disconnect the device?
URL:
http://digital.ni.com/public.nsf/allkb/1D120A90884C25AF862573A700602459
How Do I Select Configurations and Resistances of Strain Gauges in My FPGA VI for an NI 9237?
When using an NI 9237 module in an FPGA target, I don’t see a way to specify the resistance of my strain gauges or how to configure the module for quarter bridge measurement.
URL:
http://digital.ni.com/public.nsf/allkb/4E06A09A826895D98625738D006305FF
How Do I Detect an Open Thermocouple Using the NI-9211?
I have read in the user manual for the NI-9211 that the module can detect open thermocouples. How do I program my application to work with this functionality?
URL:
http://digital.ni.com/public.nsf/allkb/67E93D764EC9C38086257387004EADF6
Warning 200045 When Using NI-9237 in NI cDAQ-9172
When I use my NI-9237 in a NI cDAQ-9172 chassis I receive the following warning:"Warning 200045 occurredPossible Reason(s):Measurements: EEPROM of the device appears to be corrupt. Contact National
URL:
http://digital.ni.com/public.nsf/allkb/26A60C1D0DFF711A8625738500582D03
Channel Names Cause Incorrect Analog Output on NI USB DAQ Devices
When generating a voltage on the analog output of my USB devices (such as the USB-6008/9, cDAQ 9263) I notice that if the channels in my task have a numeric value at the end of the channel name, then I generate incorrect values. Why is this and how can I fix it?
URL:
http://digital.ni.com/public.nsf/allkb/061D00FB903F2F6586257361006C5505
Sort by:
Date (Most recent)
Title (A-Z)
11-20 of
71
Previous
|
Next
Search KnowledgeBase Documents: