Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Document Languages
: English [remove] ,
Hardware
: Signal Conditioning Other [remove] ,
11-20 of 78
KnowledgeBase [see results below]. To refine your results, select another category.
Software
Driver Software (10)
LabVIEW Development Systems (3)
Utility Software (1)
Hardware
SC Analog Accessories (20)
SC Digital Accessories (4)
SC Cable Adapters (3)
SSR Series (14)
5B Series (31)
6B Series (4)
Question Type
Bug Fix/ Error Message/ Error Code (3)
FAQ (4)
Install/Config (7)
Programming (14)
Specifications/ Documentation (46)
Unexpected Behavior/ Bad Reading (4)

Sort by:
11-20 of 78
|
Using SC-206X Boards with M Series DAQ Devices Using the SHC-68-68-EPM cable with an 68M-50F adaptor, connect the DAQ device to one of the two 50-pin ribbon cable connectors (J1 and J2) of the SC-2050 board. URL: http://digital.ni.com/public.nsf/allkb/9D688D259C0D796748256F7D0080FC4F
What Are Flyback Diodes and Why Are They Used? I have an output SSR module and I was told that I need to use flyback diodes to protect the system. What are these diodes and why are they used? URL: http://digital.ni.com/public.nsf/allkb/336D3653F6B6387386256F36005BE09F
Accessories in Traditional NI-DAQ and NI-DAQmx NI Home 3 ratings: 4.33 out of 5 Rate this Document Accessories in Traditional NI-DAQ and NI-DAQmx Hardware: Multifunction DAQ (MIOConnector Blocks>>BNC-2080, Multifunction DAQ (MIOConnector Blocks>>BNC-2090, Multifunction DAQ (MIOConnector Blocks>>BNC-2110, Multifunction DAQ (MIOConnector URL: http://digital.ni.com/public.nsf/allkb/B50A1CA411D90EAD86256F1E0065FDC0
Can I Use my SC-2311 with an M-Series Device? Problem: Can I use the SC-2311 with an M-series device? Solution: Yes, the SC-2311 is pin-compatible with M-series devices, and therefore can be used in DAQmx with 5B and SSR modules. You cannot add the SC-2311 as an accessory in DAQmx, but this is not a requirement for using the modules. URL: http://digital.ni.com/public.nsf/allkb/6CDB32DAFD77D4AB86256F1D004DE97F
Can I Use my SC-2311 with an M-Series Device? Problem: Can I use the SC-2311 with an M-series device? Solution: Yes, the SC-2311 is pin-compatible with M-series devices, and therefore can be used in DAQmx with 5B and SSR modules. You cannot add the SC-2311 as an accessory in DAQmx, but this is not a requirement for using the modules. URL: http://digital.ni.com/public.nsf/allkb/C022935B4593113286257116005719B6
E-Series Common Mode Voltage Limitations I am performing an analog acquisition using a National Instruments data acquisition board and it says that I can input up to 10 V differentially. Does this mean that I can connect 100 V on one lead and 110 V on another lead? URL: http://digital.ni.com/public.nsf/allkb/1A9FB36240EAB28286256F1800063138
Configuring SC-2311 in MAX Problem: How can I configure my SC-2311 in MAX? Solution: If you want to configure SC-2311 using MAX you should be able to do it under Traditional NI-DAQ Devices. 1. Right click on the device under Traditional NI-DAQ Devices and go to Properties. 2. You will have a configuration window pop up 3. URL: http://digital.ni.com/public.nsf/allkb/CD1E01FA5FF7385586256F0F0059EE56
Why Does My RLY-01 SCC Module Default to the Normally Open (NO) State? Problem: Why Does My RLY-01 SCC Module Default to the Normally Open (NO) State? Solution: The RLY-01 module is driven by the DIO lines on Multifunction DAQ boards. The state of the RLY-01 module is not guaranteed until the board's DIO lines are in output mode. URL: http://digital.ni.com/public.nsf/allkb/C9D0249BF68667EA86256ED6004F2FCC
GPIB-USB-B Grounding and Isolation I have a system setup where the PC that holds the GPIB-USB-B is grounded at a different potential than the GPIB instrument I am using. I have used PCI-GPIB in place of the GPIB-USB-B in the same PC for years without issues, but I had to send the GPIB-USB-B in for repair. Is there a problem URL: http://digital.ni.com/public.nsf/allkb/2AC7A5E028F1B09486256EB5006AB934
Remote Sense Inputs on the SCXI-1520 and PXI-4220 I noticed two input terminals on my SCXI-1314 terminal block: RS+ and RS- What are these terminals and how do I use them? URL: http://digital.ni.com/public.nsf/allkb/724FDFA5FEA4FE9586256E9000762B64
Sort by:
11-20 of 78
|