Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Document Languages
: English [remove] ,
Hardware
: Counter/Timers (TIO) [remove] ,
21-30 of 150
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (5)
Driver Software (14)
Measurement Studio (1)
Utility Software (3)
Hardware
Devices (72)
Connectivity (23)
Question Type
Bug Fix/ Error Message/ Error Code (11)
FAQ (15)
Install/Config (8)
Programming (32)
Specifications/ Documentation (75)
Unexpected Behavior/ Bad Reading (9)

Sort by:
21-30 of 150
|
What is an Avalanche Diode and Why Do I Read a Negative Voltage? Why do I measure a negative voltage when using an avalanche diode? Can I fix this in software? URL: http://digital.ni.com/public.nsf/allkb/9D9B430028AA28AA862572260005CCDF
Error -200251: 'No DMA Channels Available' When Using Multiple Counters I am doing more than three simultaneous counter input tasks on a NI 6602 or NI 6608, or I am doing more than one simultaneous counter input task on a PCI-6601. After adding an additional task and running, the following error occurs at DAQmx Start URL: http://digital.ni.com/public.nsf/allkb/6503B2EFA2CB867186257219007DB643
Where Is the Calibration Software for my PXI-6608? Within the calibration manual for the PXI-6608, it tells me to download the calibration software from ni.com/support/calibrat. However, there is no software available on the page for the 6608. Where do I find this software? URL: http://digital.ni.com/public.nsf/allkb/BE269114E1529239862571D1007B210B
Using One Counter to Generate a Retriggerable Finite Digital Pulse Train with a PCI-6602 and DAQmx Is it possible to create a finite digital pulse train using only one counter on my PCI-6602 using DAQmx? URL: http://digital.ni.com/public.nsf/allkb/4A9AF19480E50C6D862571B70058142A
Determining in Hardware When the Terminal Count of a Counter is Reached How can I determine in hardware when the terminal count of my counter is reached? URL: http://digital.ni.com/public.nsf/allkb/1FA39908C687A5F58625713C00064464
Enabling the Digital Debounce Filters for TIO Devices in NI-DAQmx How do I enable the digital filters for the NI 66xx or M-Series devices in NI-DAQmx? URL: http://digital.ni.com/public.nsf/allkb/220083B08217CFD686257131007E5D2C
Error at Line Set Attribute for TIO Application I have a Traditional DAQ Counter/Timer VI that worked in LabVIEW 6.1 but errors at Line Set Attribute in LabVIEW 8 URL: http://digital.ni.com/public.nsf/allkb/47A14AF259407A3A8625712700027582
Global Positioning System (GPS) Timestamp from the PXI-6608 Shows a 90ms Delay 0. To return the accurate GPS timestamp, subtract 90 ms from the value measured by the PXI-6608. URL: http://digital.ni.com/public.nsf/allkb/C916F1749B938B28862571070083A4F1
Triggered Buffered Counting on Multiple Cards Running Slower Than Expected I have multiple counter cards doing buffered event counting. When I use a start trigger for this acquisition it runs much slower than if I just let them start when the VIs are called. Why is this going slower than expected? URL: http://digital.ni.com/public.nsf/allkb/6D1E0EBED9123B3D86257100006DDA6E
Using the SCB-68 Breadboard and Filter Areas What is the breadboard/filter area on a SCB-68? Why and how would I use it? URL: http://digital.ni.com/public.nsf/allkb/AE4E560E2D501310862570CB0001F663
Sort by:
21-30 of 150
|