Recovering a FieldPoint Configuration from the IAK File
My FieldPoint system has lost its configuration, but I have a copy of the IAK file on my PC. Can I use this to recover my FieldPoint's configuration?
URL: http://digital.ni.com/public.nsf/allkb/2EF82CA062692F4886257325008067BC
|
What Software Needs to be Installed to Activate the FieldPoint Recommended Software Sets in MAX?
I have installed the August 2007 Driver CD or later, and I would like to use the recommended software sets for FieldPoint, but they are disabled. What software do I need to install to activate these recommended software sets?
URL: http://digital.ni.com/public.nsf/allkb/B4394A1AE038A5FF8625731B005FE34F
|
In MAX, How Can I Link my [c]FP to a New IP Address?
I have configured a compact FieldPoint system on my local subnet with plans to move it to another subnet. I save the Measurement & Automation Explorer (MAX) IAK file and import it on a computer on the new subnet with the [c]FP system. However, MAX now shows the system configuration on the
URL: http://digital.ni.com/public.nsf/allkb/EED81C50334B8023862572E4004DC06F
|
In Measurement & Automation Explorer (MAX), how can I relink my [compact]FieldPoint system to a newer IP address?
I have configured a [compact]FieldPoint system on my local subnet with plans to move it to another subnet. I save the MAX IAK file and import it on a computer on the new subnet with the [compact]FieldPoint system. However, MAX now shows the system configuration on the new subnet and an
URL: http://digital.ni.com/public.nsf/allkb/B021C0871E628928862572E4004DCE82
|
[c]FP-RTD-124 Returns Noisy or Fluctuating Measurements
Problem: Why does my [c]FP-RTD-124 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that FieldPoint and Compact FieldPoint [c]FP-RTD-124 modules may take noisy or fluctuating measurements at power up. Often, measurements stabilize after several seconds.
URL: http://digital.ni.com/public.nsf/allkb/3784655EFDDDE51E862572CF007A7D62
|
Why Do I Get Error 63 When Updating the Software on my FieldPoint?
I am using the following software: LabVIEW Real-Time 6.X FieldPoint OS 9.X Why do I get error 63 when I attempt to update the OS or installed software?
URL: http://digital.ni.com/public.nsf/allkb/80C1B751253C8F40862572CF000D36BE
|
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration?
I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but
URL: http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
|
Where Can I Find The Warranty For My NI Hardware?
I'm trying to find the warranty information for my NI hardware. Where can I find it?
URL: http://digital.ni.com/public.nsf/allkb/8341879DC763DF5886257289005D816E
|
Can the cFP-DO-401 Generate Square Wave Pulses?
I have a cFP-2000 controller and a cFP-DO-401 module. Can I output square waves with the cFP-DO-401 module of a given frequency?
URL: http://digital.ni.com/public.nsf/allkb/6AE03CAC3EAF14BE8625727C005697C4
|
What Background Communications Occur Between a Host PC and a [c]FieldPoint Controller?
Are there any background communications that occur between a FieldPoint Controller and host PC apart from what a user programs?
URL: http://digital.ni.com/public.nsf/allkb/CB1F3CD7923FBF0A86257267007413A9
|