Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Document Languages
: English [remove] ,
Hardware
: FieldPoint [remove] ,
11-20 of 322
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (17)
LabVIEW Modules (15)
LabWindows/CVI Development Systems (1)
Calibration Executive (2)
Driver Software (27)
LabVIEW Run-Time Engine (1)
LabVIEW Toolkits (1)
Lookout (4)
Measurement Studio (3)
Other NI Software (2)
More... 
Hardware
Controllers/Network Modules (138)
Analog I/O Modules (59)
Discrete I/O Modules (47)
Dual-Channel Modules (9)
Terminal Bases (3)
Question Type
Bug Fix/ Error Message/ Error Code (30)
FAQ (29)
Install/Config (52)
Programming (58)
Specifications/ Documentation (124)
Unexpected Behavior/ Bad Reading (29)

Sort by:
11-20 of 322
|
Recovering a FieldPoint Configuration from the IAK File My FieldPoint system has lost its configuration, but I have a copy of the IAK file on my PC. Can I use this to recover my FieldPoint's configuration? URL: http://digital.ni.com/public.nsf/allkb/2EF82CA062692F4886257325008067BC
What Software Needs to be Installed to Activate the FieldPoint Recommended Software Sets in MAX? I have installed the August 2007 Driver CD or later, and I would like to use the recommended software sets for FieldPoint, but they are disabled. What software do I need to install to activate these recommended software sets? URL: http://digital.ni.com/public.nsf/allkb/B4394A1AE038A5FF8625731B005FE34F
In MAX, How Can I Link my [c]FP to a New IP Address? I have configured a compact FieldPoint system on my local subnet with plans to move it to another subnet. I save the Measurement & Automation Explorer (MAX) IAK file and import it on a computer on the new subnet with the [c]FP system. However, MAX now shows the system configuration on the URL: http://digital.ni.com/public.nsf/allkb/EED81C50334B8023862572E4004DC06F
In Measurement & Automation Explorer (MAX), how can I relink my [compact]FieldPoint system to a newer IP address? I have configured a [compact]FieldPoint system on my local subnet with plans to move it to another subnet. I save the MAX IAK file and import it on a computer on the new subnet with the [compact]FieldPoint system. However, MAX now shows the system configuration on the new subnet and an URL: http://digital.ni.com/public.nsf/allkb/B021C0871E628928862572E4004DCE82
[c]FP-RTD-124 Returns Noisy or Fluctuating Measurements Problem: Why does my [c]FP-RTD-124 return noisy or fluctuating measurements? Solution: National Instruments recently discovered that FieldPoint and Compact FieldPoint [c]FP-RTD-124 modules may take noisy or fluctuating measurements at power up. Often, measurements stabilize after several seconds. URL: http://digital.ni.com/public.nsf/allkb/3784655EFDDDE51E862572CF007A7D62
Why Do I Get Error 63 When Updating the Software on my FieldPoint? I am using the following software: LabVIEW Real-Time 6.X FieldPoint OS 9.X Why do I get error 63 when I attempt to update the OS or installed software? URL: http://digital.ni.com/public.nsf/allkb/80C1B751253C8F40862572CF000D36BE
Why Do My [c]FP-TC-120 Modules Keep Failing Calibration? I am using Calibration Executive to check the calibration of my [c]FP-TC-120 modules. Every time I run the test, all of my thermocouple modules fail the negative tolerance test. I found this suspicious, so I looked into the specifications. For the 20mV test, the pass/fail limit is +/-10uV but URL: http://digital.ni.com/public.nsf/allkb/2E444F0A014D4B95862572A30068CC27
Where Can I Find The Warranty For My NI Hardware? I'm trying to find the warranty information for my NI hardware. Where can I find it? URL: http://digital.ni.com/public.nsf/allkb/8341879DC763DF5886257289005D816E
Can the cFP-DO-401 Generate Square Wave Pulses? I have a cFP-2000 controller and a cFP-DO-401 module. Can I output square waves with the cFP-DO-401 module of a given frequency? URL: http://digital.ni.com/public.nsf/allkb/6AE03CAC3EAF14BE8625727C005697C4
What Background Communications Occur Between a Host PC and a [c]FieldPoint Controller? Are there any background communications that occur between a FieldPoint Controller and host PC apart from what a user programs? URL: http://digital.ni.com/public.nsf/allkb/CB1F3CD7923FBF0A86257267007413A9
Sort by:
11-20 of 322
|