Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Document Languages
: English [remove] ,
Hardware
: Switches [remove] ,
11-20 of 86
KnowledgeBase [see results below]. To refine your results, select another category.
Software
LabVIEW Development Systems (1)
Driver Software (5)
Switch Executive (2)
Utility Software (2)
Hardware
General-Purpose (24)
Multiplexer/Matrix (40)
Switch Controllers (2)
Question Type
Bug Fix/ Error Message/ Error Code (6)
FAQ (14)
Install/Config (11)
Programming (14)
Specifications/ Documentation (31)
Unexpected Behavior/ Bad Reading (10)

Sort by:
11-20 of 86
|
Length of the NI LFH160 Cable for PXI Switches What is the length of the LFH160 cable? I have looked on the ni.com product page and in the installation instructions for this part and, while the weight of the cable was listed, the length is not. URL: http://digital.ni.com/public.nsf/allkb/08D38EF6B7F518F186257486006DC434
Why Do I Get Error -1074118644 Using an NI Switch? When I configure an NI switch I get the following error: Error -1074118644 occured at niSwitch Initialized With Topology.viNo legacy device URL: http://digital.ni.com/public.nsf/allkb/8BAC537C339309C58625746E00703C08
Can I Measure Signals From My Switch Module Through the PXI Backplane? I have many signals going into my switch module and I want to measure them with my DMM. Can I measure these signals directly off the backplane? URL: http://digital.ni.com/public.nsf/allkb/16CD1D9DC3E7DA098625743B006315D5
Why does the Auto-Detect Fail to Recognize my SCXI-1163R? I am controlling a SCXI chassis with an M-Series DAQ device. Currently I have the chassis properly configured in MAX with the appropriate communicating device selected and it auto-detects and recognizes all modules except my SCXI 1163R. I have ensured that all the jumpers are in their URL: http://digital.ni.com/public.nsf/allkb/ED9E094B7996D4A58625743300606C56
Get Relay Count for Unlimited Mechanical Life Relays If the new FET (PXI 2533/2534) and SSR (PXI 2535/2536) switch modules state that they have unlimited relay life, what is the meaning of the Get Relay Count value? URL: http://digital.ni.com/public.nsf/allkb/29B855397420232B862574320078D9E7
ER-16 Not Powering On The ER-16's red power up LED is not turning on and it is not appearing in Measurement and Automation Explorer (MAX). Why won't the power LED turn on? URL: http://digital.ni.com/public.nsf/allkb/4AC03EECC0ADC53A8625742C00620A3A
Signal Connections for TB-2606 Terminal Block Where can I find the signal connections or a diagram of the terminals for the TB-2606 terminal block? URL: http://digital.ni.com/public.nsf/allkb/351180C195A77DED8625740800506462
NI PXI-2535 or PXI-2536 FET Switch Doesn't Close I am using an NI switch module with fault protected FET switches (e.g. PXI-2535 or PXI-2536). The module typically works as it should, but sometimes I notice that the signal path reads open even after a command is sent to close the switch. I've noted this can happen when using the fault pro URL: http://digital.ni.com/public.nsf/allkb/FD603AF66DCC934386257403006C4109
Protecting NI Switch Modules when Switching Inductive Loads Switching inductive loads (e.g. motors and solenoids) may produce high voltage transients in excess of the module's rated voltage. Without additional protection, these transients can interfere with module operation and impact relay life. How do I protect my switch module from these transients? URL: http://digital.ni.com/public.nsf/allkb/AB895F6C52DD73D3862573F3007FBB7C
Why Isn't Using '&' Performing Simultaneous Scanning? Normally when I use the ampersand (&) in my scan list, such as ch0->com0 & ch9->com1, my channels will connect simultaneously. On some switches (e.g. PXI-2576, SCXI-1127), it scans at the same rate as doing individual connections with ";" such as ch0->com0; URL: http://digital.ni.com/public.nsf/allkb/454AA33002593ABE862573E8005265E1
Sort by:
11-20 of 86
|