Cart
|
Help
NI Home
>
Support
> KnowledgeBase
KnowledgeBase
Select your country
Category(s) Selected
[
start over
]
Document Languages
: English [
remove
] ,
Software
: Calibration Executive [
remove
] ,
31-40 of
71
KnowledgeBase [
see results below
]. To refine your results, select another category.
Hardware
Multifunction DAQ (MIO)
(3)
Compact FieldPoint
(1)
CompactDAQ
(1)
CompactRIO
(1)
FieldPoint
(2)
Modular Instruments
(4)
PXI/CompactPCI
(1)
SCXI
(4)
Question Type
Bug Fix/ Error Message/ Error Code
(30)
FAQ
(10)
Install/Config
(11)
Programming
(11)
Specifications/ Documentation
(6)
Unexpected Behavior/ Bad Reading
(3)
Search KnowledgeBase Documents:
Sort by:
Date (Most recent)
Title (A-Z)
31-40 of
71
Previous
|
Next
Error -10635 when Running SCXI-1520 Calibration Executive Procedure with SCXI-1001 Chassis
The following error occurs when running the SCXI-1520 Calibration Executive Procedure with an SCXI-1001 Chassis.Error -10635, Error Message: invalid SCXIOpModeError: Either the SCXI operating mode specified in a configuration call is invalid, or a module is in the wrong operating mode
URL:
http://digital.ni.com/public.nsf/allkb/863A7527267B772B86256F0400532E92
Error -1074135024 In Calibration Executive Procedure For Agilent 3325B
I get Error Code -1074135024 in Calibration Executive when I'm running the procedure for the NI 4472 DSA device. At the step regarding the Agilent 3325, it gives the error message shown below.
URL:
http://digital.ni.com/public.nsf/allkb/E03677C1B01816ED86256EED0065D27A
Error 2147352573 with Calibration Executive 2.0 on Windows 2000 or ME
Why do I get Error Code 2147352573 when I try to run Calibration Executive 2.0 on Windows 2000 or ME?
URL:
http://digital.ni.com/public.nsf/allkb/3F0C69566B03F74386256EE4005B225E
Why Do I Get an Input Impedance of 750K Ohms When Calibrating a PXI-5112?
I am using a Datron/Wavetek 1281 (the 1281 is a 8.5 digit DMM) to measure the input impedance of a PXI-5112 with Calibration Executive. I expect to get an input impedance reading of 1MΩ on all ranges: 40V, 4V, and 0.4V.The problem is when I run the test, I get an input impedance of 1MΩ on
URL:
http://digital.ni.com/public.nsf/allkb/DC13A3548760A67A86256EE0002DA554
Verify Board Calibration Without Adjusting Calibration Constants
Is there a way to verify that my data acquisition device is properly calibrated without adjusting the calibration constants stored in the device's EEPROM?
URL:
http://digital.ni.com/public.nsf/allkb/C473213FAB6835F186256EDD008268CA
Calibration Executive 2.2.1 File Extractor May Cause New Procedures to Appear in the Calibration Executive Wizard
I installed the Calibration Executive 2.2.1 file extractor and it caused new procedures to appear in the Calibration Executive Wizard. Why did this happen?
URL:
http://digital.ni.com/public.nsf/allkb/20C0C9781D37AECD86256EA6004D5A15
Calibration Executive 2.2 Hangs when Opening a Report
Calibration Executive sometimes hangs when trying to open a report. The problem seems to be in the LV Run Time Engine (RTE), which is used by the report generator.
URL:
http://digital.ni.com/public.nsf/allkb/24AEFA741E9BAD2086256E9900589E5F
Error Message 'Calibration Sequence Error' when running the Calibration Procedure.
When I run the Calibration Executive procedure, the first two steps including the self-calibration are properly passed, but the third step is failing. I obtain the following message "Calibration Sequence Error", and the execution stops and a blank report is generated (see below). It occurs in
URL:
http://digital.ni.com/public.nsf/allkb/94F9A85CB634D0BD86256E8500552394
Can Calibration Executive Run on 64-bit Processors?
I would like to use NI's Calibration Executive software on a 64-bit processor, either AMD64 or Intel Itanium for example. Is this possible?
URL:
http://digital.ni.com/public.nsf/allkb/5C93D0B36E4A841986256E7700795574
Can the SCXI-1100 or 1102 be Calibrated with the Current Resistors Installed?
I have configured my SCXI-1100 for current measurements by installing the process-current resistors as shown on page 2-9 of the SCXI-1100 user manual (page 2-4 of the SCXI-1102/B/C User Manual). I would like to calibrate my SCXI module with Calibration Executive. Do I have to change this setup in