Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
KnowledgeBase

Category(s) Selected [start over]

Document Languages
: English [remove] ,
Software
: Calibration Executive [remove] ,
21-30 of 74
KnowledgeBase [see results below]. To refine your results, select another category.
Hardware
Multifunction DAQ (MIO) (3)
Compact FieldPoint (1)
CompactDAQ (1)
CompactRIO (1)
FieldPoint (2)
Modular Instruments (4)
PXI/CompactPCI (1)
SCXI (5)
Question Type
Bug Fix/ Error Message/ Error Code (30)
FAQ (11)
Install/Config (11)
Programming (11)
Specifications/ Documentation (6)
Unexpected Behavior/ Bad Reading (5)

Sort by:
21-30 of 74
|
Connecting the DAQPad-6016 or 6015 with Calibration Executive I am trying to connect the DAQPad-6016/15 for Calibration Executive. What connections do I need to make? URL: http://digital.ni.com/public.nsf/allkb/0784B1B82E57A0CF86257141005EE97E
Upgrading to Calibration Executive 3.0/3.01/3.1 I want to upgrade from Calibration Executive 2.0 to Calibration Executive 3.0/3.01/3.1. What steps do I need to follow? URL: http://digital.ni.com/public.nsf/allkb/A9CEC67A85FC97E3862571220072F36B
Why Is My SCXI Module Not Selectable In Calibration Executive? I am trying to calibrate an SCXI module in Calibration Executive. I have configured the Calibration Procedure in the setup wizard, and when I try to choose the module while setting up the Device Identifier, I cannot select it in the drop-down box. I have set up my DAQ card and SCXI chassis in MAX. URL: http://digital.ni.com/public.nsf/allkb/D98BF27357A11BEE862570E50061EF98
'No Drivers Available' Message When Calibrating Counters on DAQ Cards I am using Calibration Executive to calibrate the counters my DAQ board. The calibrator and DMM are found, but not the counter and a 'No Drivers Available' message appears. URL: http://digital.ni.com/public.nsf/allkb/47114D68CB590B89862570C8000AA72A
Remove Procedures in Calibration Executive If a folder is removed, all the boards in that category will be removed from the procedure. Example: To remove all M-Series boards go to C:\Program Files\National Instruments\Calibration Executive\procedures and remove the MIO DAQmx folder. URL: http://digital.ni.com/public.nsf/allkb/3C231981DD0411808625704C006189EA
Calibration Executive 3.0 Returns Error -18002 When Executing a Calibration Procedure I recently installed Calibration Executive 3.0. The Cal Exec application launches correctly, but when I attempt to run any of the calibration procedures, I always receive error code -18002 'The VI is not executable.' What can I do to eliminate this error? URL: http://digital.ni.com/public.nsf/allkb/0E76EBB4EFE0C25386257031006E8C25
Unknown Interface Error Calibrating FP-TC-120 with Calibration Executive I am trying to calibrate my FP-TC-120 using Calibration Executive 2.2.1 in Windows XP. Why do I receive the following error message: UNKNOWN interface error occurred at: Step: 'Adjust' In Sequence: 'Adjust' Specific Error Information: Error Code: -34123 Error Message: UNKNOWN ERROR? URL: http://digital.ni.com/public.nsf/allkb/A9175F53A45C360E86256F9B00231095
Why Do I Get Error -1074130425: 'Item Does Not Exist in the Collection' When I Try to Run Calibration Executive? Why do I get Error -1074130425: "Item Does Not Exist in the Collection" when I try to run Calibration Executive? URL: http://digital.ni.com/public.nsf/allkb/F8B99894A4259AFE86256F6B00768286
Baud Rate Settings When Calibrating an FP-TC-120 with Calibration Executive What baud rate should I set on my FieldPoint controller in order to calibrate my FP-TC-120? URL: http://digital.ni.com/public.nsf/allkb/8F0CB5E601E4D90B86256F3500673843
Calibrating FieldPoint Modules Using a FieldPoint 2000 with Calibration Executive Can I calibrate my FieldPoint modules using a FieldPoint 2000 (FP-2000) controller and calibration executive? URL: http://digital.ni.com/public.nsf/allkb/C8B6E49ED7A5D8FE86256F26005D6C2E
Sort by:
21-30 of 74
|