System Memory Requirements for Compiling LabVIEW FPGA Applications
Although this memory requirement applies to typical designs, the unique characteristics of each design affect the memory utilization. The design complexity and constraints affect whether the FPGA Module can implement the design using more or less memory.
URL: http://digital.ni.com/public.nsf/allkb/F89C3D88819B8DE68625744800815537
|
Why Do I Receive Error -42802 When Compiling My LabVIEW FPGA VI?
I have a LabVIEW FPGA VI that uses the Fixed-Point Math Library. When I try to compile, I receive Error code: -42802 (refer to details). How can I fix this?
URL: http://digital.ni.com/public.nsf/allkb/074FD972BC3ED90386257442007258B2
|
Why Does the cRIO Hangs when Resetting the Controller with System Reset?
When I set the System Reset IO to TRUE on the FPGA, my cRIO hangs. Why does this happen?
URL: http://digital.ni.com/public.nsf/allkb/C3B8A3D27D676FA08625744200528D94
|
How does Real-Time Hardware Update Its System Clock?
How and when does my Real-Time hardware (cFP, cRIO, or PXI) update its system clock?
URL: http://digital.ni.com/public.nsf/allkb/9DCFB7C0EB06CA9786257440006182E2
|
NI 9219 Convert FXP to Thermocouple VI
I am using NI-RIO 2.4 with fixed point I/O and an NI 9219 in a CompactRIO. How can I convert the FXP channel value in the real-time controller or host PC to temperature units, accounting for the CJC value?
URL: http://digital.ni.com/public.nsf/allkb/22C1D4F68DD27B6286257434005EA8F7
|
'Unable to Locate Component Error' with NI OPC Server installed with LabVIEW 8.5.1 DSC Module
When I try to add a new channel to NI OPC Servers, I get the following set of errors. Why does this happen?
URL: http://digital.ni.com/public.nsf/allkb/B94183CDA37A8270862574340013B237
|
Why Can't I Boot My Real-Time Controller From a USB Key?
I am trying to boot my desktop PC or PXI controller from a real-time (RT) USB utility drive that I created in Measurement and Automation Explorer. I set the controller to boot from USB by changing the boot order in the BIOS, but it is still not working. Why is my controller not detecting the
URL: http://digital.ni.com/public.nsf/allkb/9F71984BF5D7DCF68625742E0072797E
|
Why do I get a 'Missing Export' Error when Installing LabVIEW Real-Time 8.5 to my Multicore Target?
When I install LabVIEW Real-Time 8.5 software from my host machine, the target shows the message below on reboot.Error loading 'ftpserve.dll': Missing export '?copy@?$basic_string@DU?$char_traits@D@std@@V?$allocator@D@2@@std@@QBEIPADII@Z'
URL: http://digital.ni.com/public.nsf/allkb/9223F0CA39F995EA8625742B006FEF8D
|
Error -63001 NI-RIO FPGA Communications Occurs With DMA Transfers From Host to FPGA
I am trying to do a DMA transfer from the 900x cRIO RT controller to the cRIO FPGA. The FPGA code compiles. However, when I run the code I get a Real-Time error saying the following: Error -63001: NI-RIO FPGA Communications.Framework: (Hex
URL: http://digital.ni.com/public.nsf/allkb/257AF49E2110630F8625741F0062D292
|
What is the Correct File Path Format for LabVIEW Real-Time Targets?
I am trying to save a file on my real-time target and need to know what directory to specify for saving the file. What directory do I save the file on to make sure it is saved on the real-time target?
URL: http://digital.ni.com/public.nsf/allkb/BBCAD1AB08F1B6BB8625741F0082C2AF
|