Why Is My PCI-7344 Not Recognized After I Install Motion Assistant 1.2? I have NI-Motion 6.1.5 installed (recently installed latest update) and a PCI-7344. Everything was working fine, then I installed Motion Assistant 1.2. The device now doesn't show up in Measurement and Automation Explorer (MAX) and it shows up as an 'Unknown Device' in Windows Device Manager. What URL: http://digital.ni.com/public.nsf/allkb/4C03B2CA2306D24486256F6A007FE772
How Do I Mass Compile the LVCGen\LV71 Directory After Installing LabVIEW 7.1.1? I have one of many National Instruments software programs or hardware drivers installed. A list of relevant drivers would include but not be limited to the current versions of NI-DAQmx, NI-SCOPE, NI-FGEN, NI-DMM, NI-HSDIO, NI SignalExpress, Instrument I/O Assistant, Vision Assistant, Motion URL: http://digital.ni.com/public.nsf/allkb/8AF69867A18D0B3986256F5C0000D23D
What Do I Need to Include in My Project to Run the Generated C Code from Motion Assistant 1.2 A new and exciting feature of Motion Assistant 1.2 is that it will create C code as well as LabVIEW code. There are some steps to take to get this C code that is created as well as the necessary support files into a project so that the code can be compiled and run. URL: http://digital.ni.com/public.nsf/allkb/DF5262A85EC2819386256F160067F059
Finding an Encoder's Index Value with a Linear Actuator I am using a National Instruments motion controller. I have an encoder attached to the actuator and have wired the Index output of my encoder to my motion control setup. In general, the encoder seems to work just fine; however, when I try to perform a Find Index move, my actuator only moves a very URL: http://digital.ni.com/public.nsf/allkb/088AC20A1DBC287C86256E9300079884
Why Does Motion Assistant Exceed Velocity Constraints when Running a Contoured Move? I am running a contoured move in Motion Assistant, and when I use a Position Profile the velocity exceeds my maximum velocity specified in the Move Constraints tab. Why isn't Motion Assistant keeping motor velocity within the limits that I set? URL: http://digital.ni.com/public.nsf/allkb/A243BDF938D4406B86256E710055E012
My Jog Moves Velocity in Motion Assistant Does Not Reach the Max Velocity I Set I am using Motion Assistant and when I do a jog move the velocity set in the move constraints tab is not met. I have the slide control set to 100%. URL: http://digital.ni.com/public.nsf/allkb/2A9EC4B1CEB543CB86256D9E007B5EF5
Order of Installation for Multiple National Instruments Hardware and Software Products I have just purchased multiple National Instruments hardware and software products. Is there a preference for the order of installation of National Instruments software and hardware? URL: http://digital.ni.com/public.nsf/allkb/779E54A45478FA2C86256D0500774FCB
Evaluation Version Messages with Purchased Motion Control Module for Measurement Studio I purchased the Motion Control Module for Measurement Studio and when I run the built-in examples I get the following evaluation message: 'You have 30 days to evaluate the Measurement Studio ActiveX Controls. After this period, the controls stop functioning after 5 minutes of execution time. To URL: http://digital.ni.com/public.nsf/allkb/A1FF8BB9ADA64BA986256CE50074DA7A
How Do I Uninstall or Repair NI Software? I need to uninstall or repair some of my NI software products. How do I do this? URL: http://digital.ni.com/public.nsf/allkb/AC6ED75D3D93375686256E8E00245F0D
Slave Axis Moves When Reseting Position and Configured for Gearing When I check the reset position counter in Motion Assistant, the slave axis moves after the master axis completes its move. How do I stop this behavior? URL: http://digital.ni.com/public.nsf/allkb/0C9599A742D2F0E686256CDB004A5FE5