| Family | Bus | Analog Input Channels | Max AI Range | Analog Output Channels | Max AO Range | Digital Inputs | Digital Outputs | Digital Voltage | Max DO Current Drive |
|---|---|---|---|---|---|---|---|---|---|
| NI 6230 | PCI/PXI | 8 | ±10 V | 4 | ±10 V | 6 | 4 | 5 V TTL/CMOS | 10 mA |
| NI 6232 | PCI/PXI | 16 | ±10 V | 2 | ±10 V | 6 | 4 | 24 V (sourcing DO) | 350 mA |
| NI 6233 | PCI/PXI | 16 | ±10 V | 2 | ±10 V | 6 | 4 | 24 V (sinking DO) | 350 mA |
| NI 6236 | PCI/PXI | 4 | ±20 mA | 4 | ±10 V | 6 | 4 | 5 V TTL/CMOS | 10 mA |
| NI 6238 | PCI/PXI | 8 | ±20 mA | 2 | 0 to 20 mA | 6 | 4 | 24 V (sourcing DO) | 350 mA |
| NI 6239 | PCI/PXI | 8 | ±20 mA | 2 | 0 to 20 mA | 6 | 4 | 24 V (sinking DO) | 350 mA |
Industrial M Series multifunction DAQ devices offer a set of high-reliability features designed to automate even the most demanding applications.
These devices use digital isolation technology based on chip-scale transformers for increased signal bandwidth over slower optical isolators. Groups of channels form three “banks” (analog I/O, digital input, and digital output) that have a separate ground plane from each other and earth ground. Industrial M Series devices feature 60 VDC continuous bank isolation and 1,400 Vrms/1,950 VDC of channel-to-earth isolation withstand for up to 5 s. Isolation provides three main benefits:
Isolation electrically separates the high-voltage front end and the low-voltage back end of industrial M Series devices. Signals are passed between the two sections of the devices using digital isolators. By separating the two sections, any voltages within the isolation specifications are prevented from entering the bus section (see Figure 1). Isolation provides protection for the user, data acquisition system, and measurement data.

A voltage common to both sides of a differential circuit pair is called common-mode voltage. The differential voltage across the circuit pair is the desired signal, whereas the common voltage signal is the unwanted signal that may have been integrated into the transmission line. Isolation allows M Series industrial multifunction DAQ devices to measure signals from lines with signal plus common-mode voltage of up to 60 VDC. (Note: The maximum analog input signal voltage between positive and negative terminals for the industrial M Series devices is ±10 V.) Isolation also provides greater overall common-mode rejection ratios (CMRRs), rejecting noise up to 10 times better than a low-cost M Series device (see Figure 2).

Ground loops are one of the most common sources of noise in data acquisition applications. They occur when two connected terminals in a circuit are at different ground potentials, causing current to flow between the two points. This additional voltage can cause significant error in the measurement. When a ground loop exists, the measured voltage is the sum of the signal voltage and the potential difference between the signal source ground and the measurement system ground. This potential is generally not a DC level; therefore, the result is a noisy measurement system, often showing power-line frequency (60 Hz) components in the readings. By offering an isolated floating ground on the front end, the industrial M Series devices are able to prevent ground loops from forming.
Long cable lengths and the presence of electrical noise in industrial environments can make accurate voltage measurements difficult. As a result, industrial transducers that sense pressure, flow, proximity, and so on often emit current signals instead of voltage. Each of these current
loops contains a power source, a transducer, and one or more data acquisition devices. The current signal is typically between 4 and 20 mA, with 0 mA indicating an open circuit; power supplies are typically in the range of 24 to 30 VDC. Because all the current that flows from one lead
of the power supply must return to the other, current loops are immune to most sources of electrical noise and voltage (IR) drops along extensive cable lengths. The leads that provide power to the sensor also carry the measurement signal, greatly simplifying field wiring. NI 6236, NI 6238, and NI 6239 industrial M Series devices provide direct connectivity for current loops and loop-powered sensors with ±20 mA inputs. NI 6238 and NI 6239 devices also offer 0 to 20 mA static or waveform outputs.
Programmable debounce filters remove noise, glitches, and spikes from digital switches and relays connected to the digital input lines of the industrial M Series devices. This feature is important for applications in noisy industrial environments to prevent false readings. You can configure the programmable input filter for each digital line by setting the filter time in software. Any digital noise, glitch, or spike that is shorter than half of the specified filter time is blocked by the industrial
M Series device to prevent invalid readings.
With change detection, you can automatically trigger your software application to perform a digital read operation upon a digital change of state. A digital change of state is defined as the rising edge (0 to 1 transition) or falling edge (1 to 0 transition) on one or more digital lines. Using change detection, you can monitor for digital events with minimal processor usage. No polling is necessary because the industrial M Series device generates an interrupt to automatically wake up your application. To minimize the effects of noisy input lines, use programmable input filters in combination with change detection to eliminate spurious change-detection events caused by noise or glitches.
Using programmable power-up states, you can configure the initial digital output states in software to ensure glitch-free operation when connected to industrial actuators such as pumps, valves, motors, and relays. An industrial M Series device holds these output states after receiving power, so your computer can boot and your software application can begin running. Programmable power-up states are glitch free, meaning the outputs never go through an incorrect state during
power up. You can configure each digital line as high-output or low-output. Each industrial M Series device stores the settings in onboard nonvolatile memory and implements the power-up states instantaneously after power is applied to the device.
Industrial M Series devices feature two 32-bit, 80 MHz counter/timers capable of measuring angular position with X1, X2, and X4 angular encoders or linear position with two-pulse encoders. Each encoder can have up to three channels: an A phase, a B phase, and a Z index. When channel A leads channel B in a quadrature cycle, the counter increments, and when channel B leads channel A in a cycle, the counter decrements. A high level on channel Z causes the counter to be reloaded with a specified value. Encoder channels use digital inputs on the industrial M Series devices, which may be 5 V TTL or 24 VDC.
When you need to obtain performance beyond the capabilities of a multifunction DAQ device, National Instruments provides simultaneous sampling with the S Series and intelligent DAQ with the R Series. The S Series architecture dedicates an analog-to-digital converter (ADC) per channel to provide higher aggregate sampling rates compared to multiplexed devices. S Series devices are ideal for applications including IF digitization, transient recording, ultrasound and sonar testing, and high-energy physics.
R Series multifunction DAQ devices contain a 1/3M gate FPGA that is reconfigurable using the NI LabVIEW FPGA Module. These devices have up to eight independent 16-bit analog inputs with up to 200 kHz simultaneous sampling, up to eight independent 16-bit analog outputs with up to 1 MHz simultaneous update rates, and up to 96 digital I/O lines configurable at rates up to 40 MHz. You can customize these devices to develop capabilities such as complete control over the synchronization and timing of all signals and operations.
For a complete list of accessories, visit the product page on ni.com.
| Products | Part Number | Recommended Accessories | Part Number |
| NI PCI-6232 | |||
| NI PCI-6232 Each NI PCI-6232 requires: 1 Cable, 1 Connector Block | 779617-01 | Cable: Shielded - SH37F-37M Cable (1m) | 778621-01 |
| Connector Block: Screw Terminals - CB-37F-HVD | 779491-01 | ||
| NI PXI-6232 | |||
| NI PXI-6232 Each NI PXI-6232 requires: 1 Cable, 1 Connector Block | 779618-01 | Cable: Shielded - SH37F-37M Cable (1m) | 778621-01 |
| Connector Block: Screw Terminals - CB-37F-HVD | 779491-01 | ||
| NI PCI-6233 | |||
| NI PCI-6233 Each NI PCI-6233 requires: 1 Cable, 1 Connector Block | 779619-01 | Cable: Shielded - SH37F-37M Cable (1m) | 778621-01 |
| Connector Block: Screw Terminals - CB-37F-HVD | 779491-01 | ||
| NI PXI-6233 | |||
| NI PXI-6233 Each NI PXI-6233 requires: 1 Cable, 1 Connector Block | 779620-01 | Cable: Shielded - SH37F-37M Cable (1m) | 778621-01 |
| Connector Block: Screw Terminals - CB-37F-HVD | 779491-01 | ||
NI LabVIEW Professional Development System for Windows
|
|
NI LabWindows™/CVI for Windows
|
|
NI LabVIEW SignalExpress for Windows
|
|
NI Measurement Studio Professional Edition
|
|
NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs.
NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. NI offers a number of calibration services to help maintain the ongoing accuracy of your measurement hardware. These services allow you to be completely confident in your measurements, and help you maintain compliance to standards like ISO 9001, ANSI/NCSL Z540-1 and ISO/IEC 17025. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration.
Get answers to your technical questions using the following National Instruments resources.
While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair.
The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability.
NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may change, the extended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty.
NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Specifications listed below are typical at 25 °C unless otherwise noted.
| Analog Input | ||
|
Number of channels |
|
8 differential or 16 single ended |
|
Channel type |
|
Voltage input |
|
Ground reference |
|
AI GND |
|
ADC resolution |
|
16 bits |
|
DNL |
|
No missing codes guaranteed |
|
INL |
|
Refer to the AI Absolute Accuracy Table |
|
Sampling rate |
|
|
|
Maximum |
|
250 kS/s |
|
Minimum |
|
0 S/s |
|
Timing accuracy |
|
50 ppm of sample rate |
|
Timing resolution |
|
50 ns |
|
Input coupling |
|
DC |
|
Input range |
|
±10 V, ±5 V, ±1 V, ±0.2 V |
|
Maximum working voltage for analog inputs |
|
Refer to the Maximum Working Voltage section |
|
CMRR (DC to 60 Hz) |
|
95 dB (with respect to AI GND) |
|
Input impedance |
|
|
|
Device on |
|
|
|
AI+ to AI GND |
|
>10 GΩ in parallel with 100 pF |
|
AI- to AI GND |
|
>10 GΩ in parallel with 100 pF |
|
Device off |
|
|
|
AI+ to AI GND |
|
820 Ω |
|
AI- to AI GND |
|
820 Ω |
|
Input bias current |
|
±100 pA |
|
Crosstalk (at 100 kHz) |
|
|
|
Adjacent channels |
|
-75 dB |
|
Non-adjacent channels |
-90 dB | |
|
Small signal bandwidth (-3 dB) |
700 kHz | |
|
Input FIFO size |
4,095 samples | |
|
Scan list memory |
4,095 entries | |
|
Data transfers |
DMA (scatter-gather), interrupts, programmed I/O | |
|
Overvoltage protection (AI <0..7> with respect to AI GND) |
||
|
Device on |
±25 V for up to two AI pins | |
|
Device off |
±15 V for up to two AI pins | |
|
Input current during overvoltage condition |
±20 mA max/AI pin | |
| Settling Time for Multichannel Measurements | ||
|
Accuracy, full scale step, all ranges |
|
|
|
±90 ppm of step (±6 LSB) |
|
4 μs convert interval |
|
±30 ppm of step (±2 LSB) |
|
5 μs convert interval |
|
±15 ppm of step (±1 LSB) |
|
7 μs convert interval |
| Typical Performance Graphs | |
![]() |
![]() |
![]() |
![]() |
| Analog Output | ||
|
Number of channels |
|
2 |
|
Channel type |
|
Voltage output |
|
Ground reference |
|
AO GND |
|
DAC resolution |
|
16 bits |
|
DNL |
|
±1 LSB |
|
Monotonicity |
|
16 bit guaranteed |
|
Maximum update rate |
|
|
|
1 channel |
|
500 kS/s |
|
2 channels |
|
450 kS/s per channel |
|
Timing accuracy |
|
50 ppm of sample rate |
|
Timing resolution |
|
50 ns |
|
Output range |
|
±10 V |
|
Output coupling |
|
DC |
|
Output impedance |
|
0.4 Ω |
|
Output current drive |
|
±5 mA |
|
Overdrive protection |
|
±25 V |
|
Overdrive current |
|
10 mA |
|
Power-on state |
|
±20 mV |
|
Power-on glitch |
|
0.25 V for 1 ms |
|
Power-off glitch |
|
±100 mV for 350 ms |
|
Output FIFO size |
|
8,191 samples shared among channels used |
|
Data transfers |
|
DMA (scatter-gather), interrupts, programmed I/O |
|
AO waveform modes: |
|
|
|
||
|
Settling time, full scale step, 15 ppm (1 LSB) |
|
6 μs |
|
Slew rate |
15 V/μs | |
|
Glitch energy |
||
|
Magnitude |
100 mV | |
|
Duration |
3 μs | |
| Calibration (AI and AO) | ||
|
Recommended warm-up time |
15 minutes | |
|
Calibration interval |
1 year |
AI Absolute Accuracy Table |
||||||||||
| Nominal Range | Residual Gain Error (ppm of Reading) |
Gain Tempco (ppm/°C) |
Reference Tempco |
Residual Offset Error (ppm of Range) |
Offset Tempco (ppm of Range/°C) |
INL Error (ppm of Range) |
Random Noise, σ (µVrms) |
Absolute Accuracy at Full Scale1 (µV) |
Sensitivity2 (µV) |
|
|---|---|---|---|---|---|---|---|---|---|---|
|
Positive |
Negative |
|||||||||
| 10 | -10 | 75 | 25 | 5 | 20 | 57 | 76 | 244 | 3,100 | 97.6 |
| 5 | -5 | 85 | 25 | 5 | 20 | 60 | 76 | 122 | 1,620 | 48.8 |
| 1 | -1 | 95 | 25 | 5 | 25 | 79 | 76 | 30 | 360 | 12.0 |
| 0.2 | - 0.2 | 135 | 25 | 5 | 80 | 175 | 76 | 13 | 112 | 5.2 |
|
AbsoluteAccuracy = Reading · (GainError) + Range · (OffsetError) + NoiseUncertainty GainError = ResidualAIGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal) OffsetError = ResidualAIOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INL_Error
1 Absolute accuracy at full scale on the analog input channels is determined using the following assumptions: TempChangeFromLastExternalCal = 10 °C TempChangeFromLastInternalCal = 1 °C number_of_readings = 100 CoverageFactor = 3 σ For example, on the 10 V range, the absolute accuracy at full scale is as follows: GainError = 75 ppm + 25 ppm · 1 + 5 ppm · 10 GainError = 150 ppm OffsetError = 20 ppm + 57 ppm · 1 + 76 ppm OffsetError = 153 ppm
AbsoluteAccuracy = 10 V · (GainError) + 10 V · (OffsetError) + NoiseUncertainty AbsoluteAccuracy = 3,100 µV 2 Sensitivity is the smallest voltage change that can be detected. It is a function of noise. Accuracies listed are valid for up to one year from the device external calibration. |
||||||||||
AO Absolute Accuracy Table |
||||||||
| Nominal Range | Residual Gain Error (ppm of Reading) |
Gain Tempco (ppm/°C) |
Reference Tempco |
Residual Offset Error (ppm of Range) |
Offset Tempco (ppm of Range/°C) |
INL Error (ppm of Range) |
Absolute Accuracy at Full Scale1 (µV) |
|
|---|---|---|---|---|---|---|---|---|
|
Positive |
Negative |
|||||||
| 10 | -10 | 90 | 10 | 5 | 40 | 5 | 128 | 3,230 |
|
1 Absolute Accuracy at full scale numbers is valid immediately following internal calibration and assumes the device is operating within 10 °C of the last external calibration. AbsoluteAccuracy = OutputValue · (GainError) + Range · (OffsetError) GainError = ResidualGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal) OffsetError = ResidualOffsetError + AOOffsetTempco · (TempChangeFromLastInternalCal) + INL_Error |
||||||||
| Digital I/O/PFI | ||
| Static Characteristics | ||
|
Number of channels |
10 total | |
|
Input |
6 (PFI <0..5>/P0.<0..5>) | |
|
Output |
4 (PFI <6..9>/P1.<0..3>) | |
|
Direction control |
Fixed, lines are unidirectional | |
| PFI/Port 0/Port 1 Functionality | ||
|
PFI <0..5>/P0.<0..5> |
Static digital input, timing input | |
|
PFI <6..9>/P1.<0..3> |
Static digital output, timing output | |
|
Timing output sources |
Many AI, AO, counter, timing signals | |
|
Debounce filter settings |
125 ns, 6.425 μs, 2.54 ms, disable; high and low transitions; selectable per input | |
| Digital Input (Port 0) | ||
|
Number of channels |
6 | |
|
Ground reference |
P0.GND | |
|
Input voltage range |
0 to 30 V | |
|
Minimum pulse width for timing signal |
0.5 μs | |
|
Logic "0" level |
0 V to 4 V | |
|
Logic "1" level |
10 V to 30 V | |
|
Minimum input impedance |
3.3 kΩ | |
|
Typical input current |
7 mA at 24 V input 2.5 mA at 8 V input |
|
|
Maximum input current |
9 mA | |
|
Propagation delay |
||
|
Low to high |
150 ns, typical | |
|
High to low |
100 ns, typical | |
| Digital Output (Port 1) | ||
|
Number of channels |
4 | |
|
Ground reference |
P1.GND | |
|
Digital output type1 |
||
|
NI 6232 |
DO source | |
|
NI 6233 |
DO sink | |
| 1 Refer to the NI 6232 Digital I/O Connections and NI 6233 Digital I/O Connections figures. | ||
The NI 6232 Digital I/O Connections and NI 6233 Digital I/O Connections figures show P0.<0..5> and P1.<0..3> on the NI 6232 and NI 6233 devices, respectively
![]() NI 6232 Digital I/O Connections |
![]() NI 6233 Digital I/O Connections |
|
Maximum external supply voltage (P1.VCC) |
30 V | |
|
On state saturation voltage |
1.6 V maximum at 350 mA | |
|
Off state leakage |
50 μA | |
|
Maximum current |
100 mA for each line for simultaneous usage, 350 mA for single line usage | |
|
Minimum pulse width for timing signal |
||
|
NI 6232 (source output) |
5 μs | |
|
NI 6233 (sink output) |
1.25 μs | |
|
Propagation delay |
||
|
NI 6232 (source output) |
||
|
Open to close |
0.45 μs | |
|
Close to open |
2.15 μs | |
|
NI 6233 (sink output) |
||
|
Open to close |
0.4 μs | |
|
Close to open |
0.4 μs |
| General-Purpose Counter/Timers | ||
|
Number of counter/timers |
2 | |
|
Resolution |
32 bits | |
|
Counter measurements |
Edge counting, pulse, semi-period, period, two-edge separation | |
|
Position measurements |
X1, X2, X4 quadrature encoding with Channel Z reloading; two-pulse encoding | |
|
Output applications |
Pulse, pulse train with dynamic updates, frequency division,equivalent time sampling | |
|
Internal base clocks |
80 MHz, 20 MHz, 0.1 MHz | |
|
External base clock frequency |
0 MHz to 20 MHz | |
|
Base clock accuracy |
50 ppm | |
|
Inputs |
Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down | |
|
Routing options for inputs |
Any input PFI, RTSI, PXI_TRIG, PXI_STAR, many internal signals | |
|
FIFO |
2 samples | |
|
Data transfers |
Dedicated scatter-gather DMA controller for each counter/timer; interrupts; programmed I/O |
| Frequency Generator | ||
|
Number of channels |
1 | |
|
Base clocks |
10 MHz, 100 kHz | |
|
Divisors |
1 to 16 | |
|
Base clock accuracy |
50 ppm | |
| Output can be available on any output PFI or RTSI terminal. | ||
| Phase-Locked Loop (PLL) | ||
|
Number of PLLs |
1 | |
|
Reference signal |
PXI_STAR, PXI_CLK10, RTSI <0..7> | |
|
Output of PLL |
80 MHz Timebase; other signals derived from 80 MHz Timebase including 20 MHz and 100 kHz Timebases |
| External Digital Triggers | ||
|
Source |
Any input PFI, RTSI, PXI_TRIG, PXI_STAR | |
|
Polarity |
Software-selectable for most signals | |
|
Analog input function |
Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase | |
|
Analog output function |
Start Trigger, Pause Trigger, Sample Clock, Sample Clock Timebase | |
|
Counter/timer functions |
Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down |
| Device-to-Device Trigger Bus | ||
|
PCI devices |
RTSI <0..7>1 | |
|
PXI devices |
PXI_TRIG <0..7>, PXI_STAR | |
|
Output selections |
10 MHz Reference Clock; frequency generator output; many internal signals | |
|
Debounce filter settings |
125 ns, 6.425 μs, 2.54 ms, disabled; high and low transitions selectable per input | |
|
1 In other sections of this document, RTSI refers to RTSI <0..7> for PCI devices or PXI_TRIG <0..7> for PXI devices. |
||
| Bus Interface | ||
|
PCI or PXI |
3.3 V or 5 V signal environment | |
|
PXI-6232/6233 devices can be installed in PXI slots or PXI Express hybrid slots. |
||
|
DMA channels |
4, analog input, analog output, counter/timer 0, counter/timer 1 | |
| Power Requirements | ||
|
Current draw from bus during no-load condition |
||
|
+5 V |
0.7 A | |
|
+12 V |
20 mA | |
|
Current draw from bus during AI and AO overvoltage condition |
||
|
+5 V |
0.95 A | |
|
+12 V |
20 mA |
| Physical Requirements | ||
|
Printed circuit board dimensions |
||
|
NI PCI-6232/6233 |
9.7 cm × 15.5 cm (3.8 in. × 6.1 in.) | |
|
NI PXI-6232/6233 |
Standard 3U PXI | |
|
Weight |
||
|
NI PCI-6232/6233 |
103 g (3.6 oz) | |
|
NI PXI-6232/6233 |
142 g (5.0 oz) | |
|
I/O connector |
37-pin D-SUB |
| Maximum Working Voltage1 | ||
|
Channel-to-earth ground2 |
||
|
Continuous |
≤30 Vrms/60 VDC Measurement Category3 | |
|
Withstand |
≤840 Vrms/1200 VDC, verified by a 5 s dielectric withstand test | |
|
Continuous |
≤30 Vrms/60 VDC Measurement Category I4 | |
|
Withstand |
≤1,400 Vrms/1,950 VDC, verified by a 5 s dielectric withstand test | |
|
Analog channel to AI GND/AO GND (in the NI 6232/6233 Maximum Working Voltage figure, |Va - Vb|) |
≤11 V, Measurement Category I3 | |
|
Digital channel to P1.GND/P0.GND (in the NI 6232/6233 Maximum Working Voltage figure, |Vc - V|d or |Ve - Vf|) |
≤30 V, Measurement Category I3 | |
|
Caution This device is rated for Measurement Category I and the voltage across the isolation barrier is limited to no greater than 30 Vrms/60 VDC/42.4 Vpk continuous. Do not use for measurements within Categories II, III, or IV. |
||
![]() NI 6232/6233 Maximum Working Voltage |
||
| 1 Maximum working voltage refers to the signal voltage plus the common-mode voltage. | ||
| 2 In the NI 6232/6233 Maximum Working Voltage figure, |Va – Vh|, |Vc – Vh|, and |Ve – Vh|. | ||
| 3 Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. | ||
| 4 In the NI 6232/6233 Maximum Working Voltage figure, |Va – Vg|, |Vc – Vg|, and |Ve – Vg|. | ||
| Environmental | ||
|
Maximum altitude |
2,000 m (at 25 °C ambient temperature) | |
|
Pollution Degree |
2 | |
|
Indoor use only. |
||
| Operating Environment | ||
|
Ambient temperature range |
0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) | |
|
Relative humidity range |
10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) | |
| Storage Environment | ||
|
Ambient temperature range |
-40 to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) | |
|
Relative humidity range |
5% to 95% noncondensing (Tested in accordance with IEC-60068-2-56.) | |
| Shock and Vibration (PXI Only) | ||
|
Operational shock |
30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) | |
|
Random vibration |
||
|
Operating |
5 to 500 Hz, 0.3 grms | |
|
Nonoperating |
5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) | |
| Safety |
|
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: |
|
|
|
Note For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. |
| Electromagnetic Compatibility |
| This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: |
|
|
|
|
Note For EMC compliance, operate this device according to product documentation. |
| CE Compliance |
|
This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: |
|
|
|
Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. |
| Waste Electrical and Electronic Equipment (WEEE) |
|
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. |
![]() |
| NI PCI/PXI-6232 Pinout |
![]() |
| NI PCI/PXI-6233 Pinout |
©2008 National Instruments. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.