Technical Sales
United States
(866) 531-6285
info@ni.com
Requirements and Compatibility | Ordering Information | Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com.

Last Revised: 2008-10-30 09:36:31.0

Industrial M Series Multifunction DAQ – 16-Bit, ±10 V/±20 mA Analog I/O, 5 V/24 V Digital I/O

  • Up to sixteen ±10 V or eight ±20 mA analog inputs at 16 bits, 250 kS/s
  • Up to four ±10 V or two 0 to 20 mA analog outputs at 16 bits, 500 kS/s (6 μs full-scale settling time)
  • 6 digital input and 4 digital output channels, 24 V (sourcing or sinking) or 5 V TTL/CMOS
  • Two 32-bit, 80 MHz counter/timers
  • Programmable input range (±10, ±5, ±1, ±0.2 V) per channel
  • NI-MCal calibration technology for improved measurement accuracy
  • 60 VDC continuous bank isolation, 1,400 Vrms/1,950 VDC channel-to-bus, isolation withstand for 5 s
  • Per-channel selectable debounce filters for digital input lines and programmable power-up states for digital outputs

Overview

NI M Series industrial multifunction data acquisition (DAQ) devices combine the safety of isolation with the high-performance timing, amplification, and calibration methodologies unique to M Series devices to deliver accurate measurements and precise control. You can use industrial M Series devices for measurement, control, and design applications including measuring and controlling voltages and process currents from analog and digital sensors, transducers, relays, motors, valves, pumps, and other actuators.

Back to Top

Requirements and Compatibility

OS Information

  • Windows 2000/XP
  • Windows Vista x64/x86
  • Real-Time OS

Driver Information

  • NI-DAQmx

Software Compatibility

  • ANSI C
  • LabVIEW
  • LabVIEW Real-Time Module
  • Visual Studio .NET
  • LabWindows/CVI
  • Measurement Studio
  • Visual Basic
  • LabVIEW SignalExpress

Back to Top

Comparison Tables

FamilyBusAnalog Input ChannelsMax AI RangeAnalog Output ChannelsMax AO RangeDigital InputsDigital OutputsDigital VoltageMax DO Current Drive
NI 6230PCI/PXI8±10 V4±10 V645 V TTL/CMOS10 mA
NI 6232PCI/PXI16±10 V2±10 V6424 V (sourcing DO)350 mA
NI 6233PCI/PXI16±10 V2±10 V6424 V (sinking DO)350 mA
NI 6236PCI/PXI4±20 mA4±10 V645 V TTL/CMOS10 mA
NI 6238PCI/PXI8±20 mA20 to 20 mA6424 V (sourcing DO)350 mA
NI 6239PCI/PXI8±20 mA20 to 20 mA6424 V (sinking DO)350 mA

Back to Top

Application and Technology

Industrial Feature Set

Industrial M Series multifunction DAQ devices offer a set of high-reliability features designed to automate even the most demanding applications.

  • Isolation prevents ground loops, rejects high common-mode voltages, and protects users and equipment from high-voltage transients
  • ±20 mA current inputs provide direct connectivity for 4 to 20 mA process current loops
  • Programmable digital debounce filters eliminate glitches/spikes and remove noise
  • Change detection triggers on a digital event with minimal processor usage
  • Sourcing or sinking digital I/O with 24 V logic levels interfaces directly with industry-standard sensors and actuators
  • Programmable power-up states provide safe startup operation when connected to pumps, valves, motors, and relays
  • X1, X2, and X4 encoder inputs perform angular and linear position measurements

Isolation

These devices use digital isolation technology based on chip-scale transformers for increased signal bandwidth over slower optical isolators. Groups of channels form three “banks” (analog I/O, digital input, and digital output) that have a separate ground plane from each other and earth ground. Industrial M Series devices feature 60 VDC continuous bank isolation and 1,400 Vrms/1,950 VDC of channel-to-earth isolation withstand for up to 5 s. Isolation provides three main benefits:

  1. Safety from hazardous high voltages and transients 
  2. Rejection of common-mode voltages
  3. Removal of ground loops

Safety from High-Voltage Transients

Isolation electrically separates the high-voltage front end and the low-voltage back end of industrial M Series devices. Signals are passed between the two sections of the devices using digital isolators. By separating the two sections, any voltages within the isolation specifications are prevented from entering the bus section (see Figure 1). Isolation provides protection for the user, data acquisition system, and measurement data.

Common-Mode Voltage Rejection

A voltage common to both sides of a differential circuit pair is called common-mode voltage. The differential voltage across the circuit pair is the desired signal, whereas the common voltage signal is the unwanted signal that may have been integrated into the transmission line. Isolation allows M Series industrial multifunction DAQ devices to measure signals from lines with signal plus common-mode voltage of up to 60 VDC. (Note: The maximum analog input signal voltage between positive and negative terminals for the industrial M Series devices is ±10 V.) Isolation also provides greater overall common-mode rejection ratios (CMRRs), rejecting noise up to 10 times better than a low-cost M Series device (see Figure 2).

Ground Loop Removal

Ground loops are one of the most common sources of noise in data acquisition applications. They occur when two connected terminals in a circuit are at different ground potentials, causing current to flow between the two points. This additional voltage can cause significant error in the measurement. When a ground loop exists, the measured voltage is the sum of the signal voltage and the potential difference between the signal source ground and the measurement system ground. This potential is generally not a DC level; therefore, the result is a noisy measurement system, often showing power-line frequency (60 Hz) components in the readings. By offering an isolated floating ground on the front end, the industrial M Series devices are able to prevent ground loops from forming.

4 to 20 mA Process Current Loops

Long cable lengths and the presence of electrical noise in industrial environments can make accurate voltage measurements difficult. As a result, industrial transducers that sense pressure, flow, proximity, and so on often emit current signals instead of voltage. Each of these current
loops contains a power source, a transducer, and one or more data acquisition devices. The current signal is typically between 4 and 20 mA, with 0 mA indicating an open circuit; power supplies are typically in the range of 24 to 30 VDC. Because all the current that flows from one lead
of the power supply must return to the other, current loops are immune to most sources of electrical noise and voltage (IR) drops along extensive cable lengths. The leads that provide power to the sensor also carry the measurement signal, greatly simplifying field wiring. NI 6236, NI 6238, and NI 6239 industrial M Series devices provide direct connectivity for current loops and loop-powered sensors with ±20 mA inputs. NI 6238 and NI 6239 devices also offer 0 to 20 mA static or waveform outputs.

Programmable Debounce Filters

Programmable debounce filters remove noise, glitches, and spikes from digital switches and relays connected to the digital input lines of the industrial M Series devices. This feature is important for applications in noisy industrial environments to prevent false readings. You can configure the programmable input filter for each digital line by setting the filter time in software. Any digital noise, glitch, or spike that is shorter than half of the specified filter time is blocked by the industrial
M Series device to prevent invalid readings. 

Change-of-State Detection 

With change detection, you can automatically trigger your software application to perform a digital read operation upon a digital change of state. A digital change of state is defined as the rising edge (0 to 1 transition) or falling edge (1 to 0 transition) on one or more digital lines. Using change detection, you can monitor for digital events with minimal processor usage. No polling is necessary because the industrial M Series device generates an interrupt to automatically wake up your application. To minimize the effects of noisy input lines, use programmable input filters in combination with change detection to eliminate spurious change-detection events caused by noise or glitches.

Programmable Power-Up States

Using programmable power-up states, you can configure the initial digital output states in software to ensure glitch-free operation when connected to industrial actuators such as pumps, valves, motors, and relays. An industrial M Series device holds these output states after receiving power, so your computer can boot and your software application can begin running. Programmable power-up states are glitch free, meaning the outputs never go through an incorrect state during
power up. You can configure each digital line as high-output or low-output. Each industrial M Series device stores the settings in onboard nonvolatile memory and implements the power-up states instantaneously after power is applied to the device.

Quadrature Encoder Measurements

Industrial M Series devices feature two 32-bit, 80 MHz counter/timers capable of measuring angular position with X1, X2, and X4 angular encoders or linear position with two-pulse encoders. Each encoder can have up to three channels: an A phase, a B phase, and a Z index. When channel A leads channel B in a quadrature cycle, the counter increments, and when channel B leads channel A in a cycle, the counter decrements. A high level on channel Z causes the counter to be reloaded with a specified value. Encoder channels use digital inputs on the industrial M Series devices, which may be 5 V TTL or 24 VDC.

Simultaneous and Intelligent Data Acquisition

When you need to obtain performance beyond the capabilities of a multifunction DAQ device, National Instruments provides simultaneous sampling with the S Series and intelligent DAQ with the R Series. The S Series architecture dedicates an analog-to-digital converter (ADC) per channel to provide higher aggregate sampling rates compared to multiplexed devices. S Series devices are ideal for applications including IF digitization, transient recording, ultrasound and sonar testing, and high-energy physics.

R Series multifunction DAQ devices contain a 1/3M gate FPGA that is reconfigurable using the NI LabVIEW FPGA Module. These devices have up to eight independent 16-bit analog inputs with up to 200 kHz simultaneous sampling, up to eight independent 16-bit analog outputs with up to 1 MHz simultaneous update rates, and up to 96 digital I/O lines configurable at rates up to 40 MHz. You can customize these devices to develop capabilities such as complete control over the synchronization and timing of all signals and operations.

 


Back to Top

Ordering Information

For a complete list of accessories, visit the product page on ni.com.

ProductsPart NumberRecommended AccessoriesPart Number
NI PCI-6232
NI PCI-6232
Each NI PCI-6232 requires: 1 Cable, 1 Connector Block
779617-01Cable: Shielded - SH37F-37M Cable (1m)778621-01
Connector Block: Screw Terminals - CB-37F-HVD779491-01
NI PXI-6232
NI PXI-6232
Each NI PXI-6232 requires: 1 Cable, 1 Connector Block
779618-01Cable: Shielded - SH37F-37M Cable (1m)778621-01
Connector Block: Screw Terminals - CB-37F-HVD779491-01
NI PCI-6233
NI PCI-6233
Each NI PCI-6233 requires: 1 Cable, 1 Connector Block
779619-01Cable: Shielded - SH37F-37M Cable (1m)778621-01
Connector Block: Screw Terminals - CB-37F-HVD779491-01
NI PXI-6233
NI PXI-6233
Each NI PXI-6233 requires: 1 Cable, 1 Connector Block
779620-01Cable: Shielded - SH37F-37M Cable (1m)778621-01
Connector Block: Screw Terminals - CB-37F-HVD779491-01

Back to Top

Software Recommendations

NI LabVIEW Professional Development System for Windows

  • Easy-to-use graphical development environment
  • Tight integration with a wide range of measurement hardware
  • Rapid user interface development for displaying live data
  • Extensive signal processing, analysis, and math functionality
  • Source code control integration and code complexity metrics
  • Support for Windows 2000/XP/Vista/7 (32-bit) and Windows Vista/7 (64-bit)

NI LabWindows™/CVI for Windows

  • Real-time advanced 2D graphs and charts with support for Windows Vista/XP/2000
  • Complete hardware compatibility with IVI, VISA, DAQ, GPIB, and serial
  • Analysis tools for array manipulation, signal processing statistics, and curve fitting
  • Simplified cross-platform communication with network variables
  • Measurement Studio .NET tools (included in LabWindows/CVI Full only)
  • The mark LabWindows is used under a license from Microsoft Corporation.

NI LabVIEW SignalExpress for Windows

  • Quickly configure projects without programming
  • Control over 400 PC-based and stand-alone instruments
  • Log data from more than 250 data acquisition devices
  • Perform basic signal processing, analysis, and file I/O
  • Scale your application with automatic LabVIEW code generation
  • Create custom reports or easily export data to LabVIEW, DIAdem or Microsoft Excel

NI Measurement Studio Professional Edition

  • Base analysis and instrumentation components for Microsoft Visual Basic, Visual C#, and Visual C++
  • Cross-platform communication with network variables
  • Scientific user interface controls
  • Code-generating DAQ Assistant and Instrument I/O Assistant
  • Acquire data from GPIB, serial, Ethernet, and plug-in data acquisition devices
  • Requires Microsoft Visual Studio 2008/2005/.NET 2003 or Visual Studio 6.0

Back to Top

Support and Services

System Assurance Programs

NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs.


Calibration

NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. NI offers a number of calibration services to help maintain the ongoing accuracy of your measurement hardware. These services allow you to be completely confident in your measurements, and help you maintain compliance to standards like ISO 9001, ANSI/NCSL Z540-1 and ISO/IEC 17025. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration.


Technical Support

Get answers to your technical questions using the following National Instruments resources.

  • Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the world and speak the local language.
  • Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about.
  • Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you.


Repair

While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair.


Training and Certifications

The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability.

  • Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers.
  • On-site training at your facility - an excellent option to train multiple employees at the same time.
  • Online instructor-led training - lower-cost, remote training if classroom or on-site courses are not possible.
  • Course kits - lowest-cost, self-paced training that you can use as reference guides.
  • Training memberships and training credits - to buy now and schedule training later.
Visit ni.com/training for more information.



Extended Warranty

NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may change, the extended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty.


OEM

NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem.


Alliance

Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.


Back to Top

Detailed Specifications

Specifications listed below are typical at 25 °C unless otherwise noted.

Analog Input    

Number of channels

 

8 differential or 16 single ended

Channel type

 

Voltage input

Ground reference

 

AI GND

ADC resolution

 

16 bits

DNL

 

No missing codes guaranteed

INL

 

Refer to the AI Absolute Accuracy Table

Sampling rate

 

 

Maximum

 

250 kS/s

Minimum

 

0 S/s

Timing accuracy

 

50 ppm of sample rate

Timing resolution

 

50 ns

Input coupling

 

DC

Input range

 

±10 V, ±5 V, ±1 V, ±0.2 V

Maximum working voltage for analog inputs

 

Refer to the Maximum Working Voltage section

CMRR (DC to 60 Hz)

 

95 dB (with respect to AI GND)

Input impedance

 

 

Device on

 

 

AI+ to AI GND

 

>10 GΩ in parallel with 100 pF

AI- to AI GND

 

>10 GΩ in parallel with 100 pF

Device off

 

 

AI+ to AI GND

 

820 Ω

AI- to AI GND

 

820 Ω

Input bias current

 

±100 pA

Crosstalk (at 100 kHz)

 

 

Adjacent channels

 

-75 dB

Non-adjacent channels

  -90 dB

Small signal bandwidth (-3 dB)

  700 kHz

Input FIFO size

  4,095 samples

Scan list memory

  4,095 entries

Data transfers

  DMA (scatter-gather), interrupts, programmed I/O

Overvoltage protection (AI <0..7> with respect to AI GND)

 

Device on

  ±25 V for up to two AI pins

Device off

  ±15 V for up to two AI pins

Input current during overvoltage condition

  ±20 mA max/AI pin
Settling Time for Multichannel Measurements    

Accuracy, full scale step, all ranges

 

 

±90 ppm of step (±6 LSB)

 

4 μs convert interval

±30 ppm of step (±2 LSB)

 

5 μs convert interval

±15 ppm of step (±1 LSB)

 

7 μs convert interval
Typical Performance Graphs  
Analog Output    

Number of channels

 

2

Channel type

 

Voltage output

Ground reference

 

AO GND

DAC resolution

 

16 bits

DNL

 

±1 LSB

Monotonicity

 

16 bit guaranteed

Maximum update rate

 

 

1 channel

 

500 kS/s

2 channels

 

450 kS/s per channel

Timing accuracy

 

50 ppm of sample rate

Timing resolution

 

50 ns

Output range

 

±10 V

Output coupling

 

DC

Output impedance

 

0.4 Ω

Output current drive

 

±5 mA

Overdrive protection

 

±25 V

Overdrive current

 

10 mA

Power-on state

 

±20 mV

Power-on glitch

 

0.25 V for 1 ms

Power-off glitch

 

±100 mV for 350 ms

Output FIFO size

 

8,191 samples shared among channels used

Data transfers

 

DMA (scatter-gather), interrupts, programmed I/O

AO waveform modes:

 

 
  • Non-periodic waveform
  • Periodic waveform regeneration mode from onboard FIFO
  • Periodic waveform regeneration from host buffer including dynamic update

Settling time, full scale step, 15 ppm (1 LSB)

 

6 μs

Slew rate

  15 V/μs

Glitch energy

   

Magnitude

  100 mV

Duration

  3 μs
Calibration (AI and AO)    

Recommended warm-up time

  15 minutes

Calibration interval

  1 year

AI Absolute Accuracy Table

Nominal Range Residual
Gain
Error
(ppm of
Reading)
Gain
Tempco
(ppm/°C)
Reference
Tempco
Residual
Offset
Error
(ppm of
Range)
Offset
Tempco
(ppm of
Range/°C)
INL Error
(ppm of
Range)
Random
Noise,
σ (µVrms)
Absolute
Accuracy
at
Full
Scale1 (µV)
Sensitivity2
(µV)

Positive
Full
Scale

Negative
Full
Scale

10 -10 75 25 5 20 57 76 244 3,100 97.6
5 -5 85 25 5 20 60 76 122 1,620 48.8
1 -1 95 25 5 25 79 76 30 360 12.0
0.2 - 0.2 135 25 5 80 175 76 13 112 5.2

AbsoluteAccuracy = Reading · (GainError) + Range · (OffsetError) + NoiseUncertainty

GainError = ResidualAIGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal)

OffsetError = ResidualAIOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INL_Error


1 Absolute accuracy at full scale on the analog input channels is determined using the following assumptions:

TempChangeFromLastExternalCal = 10 °C

TempChangeFromLastInternalCal = 1 °C

number_of_readings = 100

CoverageFactor = 3 σ

For example, on the 10 V range, the absolute accuracy at full scale is as follows:

GainError = 75 ppm + 25 ppm · 1 + 5 ppm · 10       GainError = 150 ppm

OffsetError = 20 ppm + 57 ppm · 1 + 76 ppm         OffsetError = 153 ppm

AbsoluteAccuracy = 10 V · (GainError) + 10 V · (OffsetError) + NoiseUncertainty      AbsoluteAccuracy = 3,100 µV

2 Sensitivity is the smallest voltage change that can be detected. It is a function of noise.

Accuracies listed are valid for up to one year from the device external calibration.

 

AO Absolute Accuracy Table

Nominal Range Residual
Gain Error
(ppm of
Reading)
Gain
Tempco
(ppm/°C)
Reference
Tempco
Residual
Offset Error
(ppm of
Range)
Offset
Tempco
(ppm of
Range/°C)
INL
Error
(ppm of
Range)
Absolute
Accuracy at
Full
Scale1
(µV)

Positive
Full
Scale

Negative
Full
Scale

10 -10 90 10 5 40 5 128 3,230

1 Absolute Accuracy at full scale numbers is valid immediately following internal calibration and assumes the device is operating within 10 °C of the last external calibration.
Accuracies listed are valid for up to one year from the device external calibration.

AbsoluteAccuracy = OutputValue · (GainError) + Range · (OffsetError)

GainError = ResidualGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal)

OffsetError = ResidualOffsetError + AOOffsetTempco · (TempChangeFromLastInternalCal) + INL_Error

Digital I/O/PFI    
Static Characteristics    

Number of channels

  10 total

Input

  6 (PFI <0..5>/P0.<0..5>)

Output

  4 (PFI <6..9>/P1.<0..3>)

Direction control

  Fixed, lines are unidirectional
PFI/Port 0/Port 1 Functionality    

PFI <0..5>/P0.<0..5>

  Static digital input, timing input

PFI <6..9>/P1.<0..3>

  Static digital output, timing output

Timing output sources

  Many AI, AO, counter, timing signals

Debounce filter settings

  125 ns, 6.425 μs, 2.54 ms, disable; high and low transitions; selectable per input
Digital Input (Port 0)    

Number of channels

  6

Ground reference

  P0.GND

Input voltage range

  0 to 30 V

Minimum pulse width for timing signal

  0.5 μs

Logic "0" level

  0 V to 4 V

Logic "1" level

  10 V to 30 V

Minimum input impedance

  3.3 kΩ

Typical input current

  7 mA at 24 V input
2.5 mA at 8 V input

Maximum input current

  9 mA

Propagation delay

   

Low to high

  150 ns, typical

High to low

  100 ns, typical
Digital Output (Port 1)    

Number of channels

  4

Ground reference

  P1.GND

Digital output type1

   

NI 6232

  DO source

NI 6233

  DO sink
1 Refer to the NI 6232 Digital I/O Connections and NI 6233 Digital I/O Connections figures.

The NI 6232 Digital I/O Connections and NI 6233 Digital I/O Connections figures show P0.<0..5> and P1.<0..3> on the NI 6232 and NI 6233 devices, respectively


NI 6232 Digital I/O Connections

NI 6233 Digital I/O Connections

Maximum external supply voltage (P1.VCC)

  30 V

On state saturation voltage

  1.6 V maximum at 350 mA

Off state leakage

  50 μA

Maximum current

  100 mA for each line for simultaneous usage, 350 mA for single line usage

Minimum pulse width for timing signal

   

NI 6232 (source output)

  5 μs

NI 6233 (sink output)

  1.25 μs

Propagation delay

   

NI 6232 (source output)

   

Open to close

  0.45 μs

Close to open

  2.15 μs

NI 6233 (sink output)

   

Open to close

  0.4 μs

Close to open

  0.4 μs
General-Purpose Counter/Timers    

Number of counter/timers

  2

Resolution

  32 bits

Counter measurements

  Edge counting, pulse, semi-period, period, two-edge separation

Position measurements

  X1, X2, X4 quadrature encoding with Channel Z reloading; two-pulse encoding

Output applications

  Pulse, pulse train with dynamic updates, frequency division,equivalent time sampling

Internal base clocks

  80 MHz, 20 MHz, 0.1 MHz

External base clock frequency

  0 MHz to 20 MHz

Base clock accuracy

  50 ppm

Inputs

  Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down

Routing options for inputs

  Any input PFI, RTSI, PXI_TRIG, PXI_STAR, many internal signals

FIFO

  2 samples

Data transfers

  Dedicated scatter-gather DMA controller for each counter/timer; interrupts; programmed I/O
Frequency Generator    

Number of channels

  1

Base clocks

  10 MHz, 100 kHz

Divisors

  1 to 16

Base clock accuracy

  50 ppm
Output can be available on any output PFI or RTSI terminal.
Phase-Locked Loop (PLL)    

Number of PLLs

  1

Reference signal

  PXI_STAR, PXI_CLK10, RTSI <0..7>

Output of PLL

  80 MHz Timebase; other signals derived from 80 MHz Timebase including 20 MHz and 100 kHz Timebases
External Digital Triggers    

Source

  Any input PFI, RTSI, PXI_TRIG, PXI_STAR

Polarity

  Software-selectable for most signals

Analog input function

  Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase

Analog output function

  Start Trigger, Pause Trigger, Sample Clock, Sample Clock Timebase

Counter/timer functions

  Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down
Device-to-Device Trigger Bus    

PCI devices

  RTSI <0..7>1

PXI devices

  PXI_TRIG <0..7>, PXI_STAR

Output selections

  10 MHz Reference Clock; frequency generator output; many internal signals

Debounce filter settings

  125 ns, 6.425 μs, 2.54 ms, disabled; high and low transitions selectable per input

1 In other sections of this document, RTSI refers to RTSI <0..7> for PCI devices or PXI_TRIG <0..7> for PXI devices.

Bus Interface    

PCI or PXI

  3.3 V or 5 V signal environment

PXI-6232/6233 devices can be installed in PXI slots or PXI Express hybrid slots.

DMA channels

  4, analog input, analog output, counter/timer 0, counter/timer 1
Power Requirements    

Current draw from bus during no-load condition

   

+5 V

  0.7 A

+12 V

  20 mA

Current draw from bus during AI and AO overvoltage condition

   

+5 V

  0.95 A

+12 V

  20 mA
Physical Requirements    

Printed circuit board dimensions

   

NI PCI-6232/6233

  9.7 cm × 15.5 cm (3.8 in. × 6.1 in.)

NI PXI-6232/6233

  Standard 3U PXI

Weight

   

NI PCI-6232/6233

  103 g (3.6 oz)

NI PXI-6232/6233

  142 g (5.0 oz)

I/O connector

  37-pin D-SUB
Maximum Working Voltage1    

Channel-to-earth ground2

   

Continuous

  ≤30 Vrms/60 VDC Measurement Category3

Withstand

  ≤840 Vrms/1200 VDC, verified by a 5 s dielectric withstand test

Channel-to-bus 4

   

Continuous

  ≤30 Vrms/60 VDC Measurement Category I4

Withstand

  ≤1,400 Vrms/1,950 VDC, verified by a 5 s dielectric withstand test

Analog channel to AI GND/AO GND (in the NI 6232/6233 Maximum Working Voltage figure, |Va - Vb|)

  ≤11 V, Measurement Category I3

Digital channel to P1.GND/P0.GND (in the NI 6232/6233 Maximum Working Voltage figure, |Vc - V|d or |Ve - Vf|)

  ≤30 V, Measurement Category I3

Caution This device is rated for Measurement Category I and the voltage across the isolation barrier is limited to no greater than 30 Vrms/60 VDC/42.4 Vpk continuous. Do not use for measurements within Categories II, III, or IV.


NI 6232/6233 Maximum Working Voltage
1 Maximum working voltage refers to the signal voltage plus the common-mode voltage.
2 In the NI 6232/6233 Maximum Working Voltage figure, |Va – Vh|, |Vc – Vh|, and |Ve – Vh|.
3 Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
4 In the NI 6232/6233 Maximum Working Voltage figure, |Va – Vg|, |Vc – Vg|, and |Ve – Vg|.
Environmental    

Maximum altitude

  2,000 m (at 25 °C ambient temperature)

Pollution Degree

  2

Indoor use only.

Operating Environment

Ambient temperature range

  0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.)

Relative humidity range

  10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.)
Storage Environment    

Ambient temperature range

  -40 to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.)

Relative humidity range

  5% to 95% noncondensing (Tested in accordance with IEC-60068-2-56.)
Shock and Vibration (PXI Only)    

Operational shock

  30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.)

Random vibration

   

Operating

  5 to 500 Hz, 0.3 grms

Nonoperating

  5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)
Safety

This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:

  • IEC 61010-1, EN-61010-1
  • UL 61010-1, CAN/CSA-C22.2 No. 61010-1

Note For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use:
  • EN 61326 EMC requirements; Minimum Immunity
  • EN 55011 Emissions; Group 1, Class A
  • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A

Note  For EMC compliance, operate this device according to product documentation.

CE Compliance

This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows:

  • 73/23/EEC; Low-Voltage Directive (safety)

  • 89/336/EEC; Electromagnetic Compatibility Directive (EMC)

Note  Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm.

 


Back to Top

Pinouts/Front Panel Connections

NI PCI/PXI-6232 Pinout



NI PCI/PXI-6233 Pinout

Back to Top