Controlling NI 4472 Excitation Current from LabVIEW
The excitation current, which you can control on a per-channel basis, is a constant 4 mA current that provides power to the onboard pre-amplifier on a variety of sensors including many accelerometers, microphones, and dynamic pressure transducers. PCB Piezotronics, a vendor of accelerometers and microphones, refers to this 4 mA excitation as "IEPE", short for Integral Electronic Piezoelectric. IEPE excitation is compatible with similar DC current-driven sensors from other vendors including Kistler, Endevco, and Bruel & Kjaer.
NOTE: The excitation current produces a significant DC offset in the data. To remove this offset, enable AC coupling on all channels supplying excitation current.
Requirements
Filename: 2178.llb
Software Requirements
Application Software: LabVIEW Full Development System 6.0
Language(s): LabVIEW
Hardware Requirements
Hardware Group: Multifunction DAQ (MIO)
Driver: Traditional NI-DAQ (Legacy) 6.9.0
Reader Comments | Submit a comment »
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).