Automated Analysis of Ultrasound Images
...diameter is typically monitored in a series of 2-5 minute bursts over a...of the vessel diameter to the R-wave spikes in the ECG trace...synchronising the measurement to the R-wave spike, it was being made...configurable) window of the R-wave in the ECG (see Fig...
|
|
Intelligent ABS Module Durability Monitoring with the NI LabVIEW FPGA Module
...with NI SCXI conditioning, an NI R Series FPGA-based system with an expansion...array (FPGA) target. The NI 9151 R Series expansion chassis loaded with several...application (the FPGA application) on the R Series card. The FPGA application monitors...
|
|
Reducing Development Time of an Aerospace Transmission Test Stand Using NI LabVIEW, SCXI, and PXI
...used an NI PXI-6220 multifunction M Series data acquisition (DAQ) module to... An NI PXI-6229 multifunction M Series DAQ module combined with 10 m cables...Data Acquisition Hardware Using R Series Intelligent Data Acquisition for Bit...
|
|
Developing a System to Analyze the Fuel Economy of a Hybrid Vehicle Using NI PXI Hardware
...data acquisition (DAQ) module, PXI-6221 multifunction M Series DAQ module, PXI-4351 high-precision temperature and voltage...the external clock and trigger signals for the PXI-6221 M Series DAQ module and the PXI-4351 temperature and voltage logger...
|
|
Creating an Automated Gasometer for the Teaching Laboratory Using NI LabVIEW
...Hawkins[2], and the frequency of oscillation is given by an equation. If all components have fixed values except resistance R (in other words, the reciprocal of the cell conductance), then the frequency is controlled by its value and, in turn, the...
|
|
Eltek Valere Reduces Test Time with NI TestStand, LabVIEW, and PXI
...TestStand, LabVIEW, LabVIEW FPGA, and R Series PXI reconfigurable I/O devices to...Mads Dahl, global test manager of R&D Test Development at Eltek Valere...a factor of 10. We selected the R Series reconfigurable I/O module for this...
|
|
Creating a High-Speed Control System to Test MEMS Microshutters Using NI LabVIEW FPGA
Synchronizing the motion of a magnet moving more than 1 m/s with the opening and closing of tens of thousands of hair-sized microelectromechanical system (MEMS) microshutters.
|
|
Designing a Computer-Based Control System for an Electromagnetic Launcher Facility Using NI Hardware and LabVIEW Software
...abort command. NI PCI-6229 M Series Data Acquisition (DAQ) Board We selected a PCI-6229 M Series DAQ board for the high-voltage power...we connected several NI cRIO-9151 R Series expansion chassis to the PXI-7811R...
|
|
Developing a Hardware-in-the-Loop, High-Speed Simulation and Data Acquisition System for ECU Testing with the NI PXI Platform and NI LabVIEW Software
...involved with the ECU signals. Instead, we chose to use NI R Series intelligent DAQ field-programmable gate array (FPGA...simulated-sensor outputs. The NI PXI-7831R and PXI-7833R R Series intelligent DAQ modules also gave us the ability to capture...
|
|
Testing Clutch Drive Plate Production with NI LabVIEW and NI Hardware
...Manufacturing, Automotive Products: DIAdem, Digital Output Modules, PCI-7811R, LabVIEW, cRIO-9151, R Series Expansion Chassis, Digital Input Modules The Challenge: Creating an end-of-line test system to provide a traceable...
|